Noncontact Sensors for Vital Signs Measurement: A Narrative Review
Medical Science Monitor · 2024
DOI: 10.12659/msm.944913 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Medical Science Monitor, 2024. Verfasst von Yoo Jin Choo und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Medicine and Rehabilitation, College of Medicine, Yeungnam University, Daegu, South Korea. Hauptthemen laut MEDLINE: Vital Signs, COVID-19. Die Arbeit wurde bisher 10-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Vital signs are crucial for monitoring changes in patient health status. This review compared the performance of noncontact sensors with traditional methods for measuring vital signs and investigated the clinical feasibility of noncontact sensors for medical use. We searched the Medical Literature Analysis and Retrieval System Online (MEDLINE) database for articles published through September 30, 2023, and used the key search terms "vital sign," "monitoring," and "sensor" to identify relevant articles. We included studies that measured vital signs using traditional methods and noncontact sensors and excluded articles not written in English, case reports, reviews, and conference presentations. In total, 129 studies were identified, and eligible articles were selected based on their titles, abstracts, and full texts. Three articles were finally included in the review, and the types of noncontact sensors used in each selected study were an impulse radio ultrawideband radar, a microbend fiber-optic sensor, and a mat-type air pressure sensor. Participants included neonates in the neonatal intensive care unit, patients with sleep apnea, and patients with coronavirus disease. Their heart rate, respiratory rate, blood pressure, body temperature, and arterial oxygen saturation were measured. Studies have demonstrated that the performance of noncontact sensors is comparable to that of traditional methods of vital signs measurement. Noncontact sensors have the potential to alleviate concerns related to skin disorders associated with traditional skin-contact vital signs measurement methods, reduce the workload for healthcare providers, and enhance patient comfort. This article reviews the medical use of noncontact sensors for measuring vital signs and aimed to determine their potential clinical applicability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Physical Medicine and Rehabilitation, College of Medicine, Yeungnam University, Daegu, South Korea.
- Department of Orthopaedic Surgery, Yeungnam University Hospital, Daegu, South Korea.
- Division of Endocrinology and Metabolism, Yeungnam University Hospital, Deagu, South Korea.
ORCID-Profile: Gun Woo Lee
Zitieren
APA
Choo, Y. J., Lee, G. W., Moon, J. S., & Chang, M. C. (2024). Noncontact Sensors for Vital Signs Measurement: A Narrative Review. Medical Science Monitor. https://doi.org/10.12659/msm.944913
Vancouver
Choo YJ, Lee GW, Moon JS, Chang MC. Noncontact Sensors for Vital Signs Measurement: A Narrative Review. Medical Science Monitor. 2024. doi:10.12659/msm.944913
BibTeX
@article{Choo2024,
author = {Choo, Yoo Jin and Lee, Gun Woo and Moon, Jun Sung and Chang, Min Cheol},
title = {Noncontact Sensors for Vital Signs Measurement: A Narrative Review},
journal = {Medical Science Monitor},
year = {2024},
doi = {10.12659/msm.944913}
}
EUVIMED