A 43-Year-Old Man with a 30-Year History of a Retained Glass Intraocular Foreign Body Presenting with Retinal Detachment
American Journal of Case Reports · 2025
DOI: 10.12659/ajcr.947369 ↗Kurz gefasst
Fallbericht in der Zeitschrift American Journal of Case Reports, 2025. Verfasst von Jilin Zhou und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, The Third People's Hospital of Changzhou, Changzhou, Jiangsu, China. Hauptthemen laut MEDLINE: Retinal Detachment, Eye Foreign Bodies, Eye Injuries, Penetrating, Glass. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
BACKGROUND This report describes the case of a 43-year-old man with a 30-year history of a retained glass intraocular foreign body (IOFB) presenting with retinal detachment. CASE REPORT We describe this case using patient history, ocular examination, and imaging, including anterior segment photographs, fundus photographs, and B-scan ultrasonography. A 43-year-old man presented with retinal detachment in the right eye. Medical history revealed that the patient had suffered an explosive injury to the right eye 30 years ago, for which he underwent surgical repair at the time of the incident. However, a glass IOFB was left in the eye, either due to an oversight during the initial treatment or an intentional decision by the treating physician. On examination, indirect ophthalmoscopy revealed a half-disc-sized retinal hole at the 9 o'clock position in the peripheral retina, along with long-standing atrophic lesions extending from 12 to 2 o'clock. Temporal macular-involving retinal detachment extending from 6 to 11 o'clock was observed. B-scan ultrasonography confirmed the presence of the glass IOFB. The patient subsequently underwent surgical treatment, including pars plana vitrectomy, removal of the IOFB, retinal reattachment, photocoagulation, and silicone oil tamponade. CONCLUSIONS Patients with open globe injuries should be carefully evaluated with the presumption of an IOFB. IOFBs may remain asymptomatic for decades, underscoring the importance of regular follow-up for patients with retained IOFBs. If complications such as retinal detachment occur, they can be managed routinely.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Ophthalmology, The Third People's Hospital of Changzhou, Changzhou, Jiangsu, China.
- Department of Ophthalmology, Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore.
- Aier School of Ophthalmology, Central South University, Changsha, Hunan, China.
- Department of Ophthalmology, Shanghai Aier Eye Hospital, Aier Eye Hospital Group, Shanghai, China.
ORCID-Profile: Sahil Thakur, Chaoxu Qian
Zitieren
APA
Zhou, J., Thakur, S., & Qian, C. (2025). A 43-Year-Old Man with a 30-Year History of a Retained Glass Intraocular Foreign Body Presenting with Retinal Detachment. American Journal of Case Reports. https://doi.org/10.12659/ajcr.947369
Vancouver
Zhou J, Thakur S, Qian C. A 43-Year-Old Man with a 30-Year History of a Retained Glass Intraocular Foreign Body Presenting with Retinal Detachment. American Journal of Case Reports. 2025. doi:10.12659/ajcr.947369
BibTeX
@article{Zhou2025,
author = {Zhou, Jilin and Thakur, Sahil and Qian, Chaoxu},
title = {A 43-Year-Old Man with a 30-Year History of a Retained Glass Intraocular Foreign Body Presenting with Retinal Detachment},
journal = {American Journal of Case Reports},
year = {2025},
doi = {10.12659/ajcr.947369}
}
EUVIMED