Local Injection of Fluid Gelatin Under Contrast-Enhanced Ultrasound Guidance for Treating Active Bleeding From the Inferior Epigastric Artery: A Case Report
American Journal of Case Reports · 2025
DOI: 10.12659/ajcr.947297 ↗Kurz gefasst
Fallbericht in der Zeitschrift American Journal of Case Reports, 2025. Verfasst von Xiaohui Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, National Clinical Research Centre for Infectious Disease, Shenzhen Third People's Hospital and the Second Hospital Affiliat…. Hauptthemen laut MEDLINE: Epigastric Arteries, Gelatin, Ultrasonography, Interventional, Hemostatics. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
BACKGROUND Injury to the inferior epigastric artery is a major complication of abdominal puncture, and continuous active bleeding from this artery can lead to hemorrhagic shock. Several studies have reported the use of contrast-enhanced ultrasound (CEUS) to diagnose active bleeding in parenchymal organs. Fluid gelatin is a new hemostatic material that can be injected into the bleeding site by using a puncture needle under the precise guidance of CEUS, which enables the implementation of local minimally invasive and appropriate hemostatic treatment. Here, we report the case of a patient in whom CEUS was used to accurately locate the bleeding site before surgery and guide local injection of fluid gelatin with a puncture needle to successfully achieve nonsurgical treatment of hemostasis. CASE REPORT A 62-year-old man with post-hepatitis B cirrhosis underwent a successful liver transplant surgery. After surgery, abdominal puncture and drainage were performed because of a large amount of peritoneal effusion due to nephrotic syndrome. The drainage fluid was bright red bloody liquid. CEUS revealed many contrast agent microbubbles extravasating from the inferior epigastric artery into peritoneal effusion along the abdominal puncture tract. Surgical suturing and applying a compression bandage failed to achieve satisfactory results. After receiving the patient's consent, thrombin and hemostatic glue were injected locally under the guidance of CEUS. Finally, hemostasis was successfully achieved. CONCLUSIONS CEUS-guided injection of fluid gelatin is a safe and effective treatment method and could serve as an effective measure for nonsurgical treatment and postoperative supplementary treatment of active bleeding from the inferior epigastric artery.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Ultrasound, National Clinical Research Centre for Infectious Disease, Shenzhen Third People's Hospital and the Second Hospital Affiliated with the Southern University of Science and Technology, Shenzhen, G…
- Department of Liver Surgery, National Clinical Research Centre for Infectious Disease, The Third People's Hospital of Shenzhen and the Second Hospital Affiliated with the Southern University of Science and Technology, S…
Zitieren
APA
Li, X., Zhao, N., Zhong, L., Zhang, Y., & Luo, Y. (2025). Local Injection of Fluid Gelatin Under Contrast-Enhanced Ultrasound Guidance for Treating Active Bleeding From the Inferior Epigastric Artery: A Case Report. American Journal of Case Reports. https://doi.org/10.12659/ajcr.947297
Vancouver
Li X, Zhao N, Zhong L, Zhang Y, Luo Y. Local Injection of Fluid Gelatin Under Contrast-Enhanced Ultrasound Guidance for Treating Active Bleeding From the Inferior Epigastric Artery: A Case Report. American Journal of Case Reports. 2025. doi:10.12659/ajcr.947297
BibTeX
@article{Li2025,
author = {Li, Xiaohui and Zhao, Ningbo and Zhong, Lin and Zhang, Yu and Luo, Yongfang},
title = {Local Injection of Fluid Gelatin Under Contrast-Enhanced Ultrasound Guidance for Treating Active Bleeding From the Inferior Epigastric Artery: A Case Report},
journal = {American Journal of Case Reports},
year = {2025},
doi = {10.12659/ajcr.947297}
}
EUVIMED