EUVIMEDEUVIMED entdecken
FallberichtOpen Access

Crossed Cerebellar Diaschisis in a Status Epilepticus Patient with Stroke-Mimicking Changes: A Case Report with Suboptimal Outcome

Arturs Balodis iD, Tatjana Rzajeva, Verners Roberts Kalējs iD, Toms Mārtiņš Smilga, Marta Pūpola

American Journal of Case Reports · 2023

DOI: 10.12659/ajcr.942715 ↗

Kurz gefasst

Fallbericht in der Zeitschrift American Journal of Case Reports, 2023. Verfasst von Arturs Balodis und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Diagnostic Radiology, Pauls Stradiņš Clinical University Hospital, Riga, Latvia. Hauptthemen laut MEDLINE: Diaschisis, Stroke, Status Epilepticus. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND Crossed cerebellar diaschisis is a rare phenomenon characterized by reduction of hemispheric cerebellar blood flow and metabolism that occurs contralateral to supratentorial injury. This finding is generally detected after ischemic stroke, but can also be observed during status epilepticus. CASE REPORT A 45-year-old woman with a history of focal epilepsy and alcohol abuse presented with an episode of seizure with initial stroke-mimicking changes and no epileptiform activity on electroencephalogram. Upon further examination, the radiological findings revealed a broad cytotoxic edema in the left hemisphere and a smaller lesion in the right cerebellum, showing a rare phenomenon of crossed cerebellar diaschisis. Later, diagnosis of status epilepticus was established. Although the initial trend of the patient's condition was negative, after weeks of therapy and intensive care, the patient slightly improved in her condition and there was a partially reversible lesion in the left cerebral hemisphere and right cerebellum. CONCLUSIONS It is crucial to detect seizures in patients with stroke-like changes on unenhanced computed tomography examination, and especially in cases in which there are no arterial occlusion on computed tomography angiography and asymmetric arterial vasodilatation are seen. Status epilepticus can mimic stroke, establishing this as a major diagnostic challenge. Although the radiological findings in the left cerebral hemisphere lesion and the right cerebellar hemisphere were similar, its characteristics on diffusion-weighted imaging and apparent diffusion coefficient value differed, raising an important question of the exact mechanics of how crossed cerebellar diaschisis occurs, as it seems to be a rare phenomenon.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DiaschisisStrokeStatus EpilepticusFemaleHumansMiddle AgedCerebellumDiffusion Magnetic Resonance Imaging

Autor:innen und Institutionen

  • Institute of Diagnostic Radiology, Pauls Stradiņš Clinical University Hospital, Riga, Latvia.
  • Department of Radiology, Rīga Stradiņš University, Riga, Latvia.
  • Clinic of Neurology, Pauls Stradiņš Clinical University Hospital, Riga, Latvia.
  • Department of Radiology, Latvian University, Riga, Latvia.

ORCID-Profile: Arturs Balodis, Verners Roberts Kalējs

Zitieren

APA

Balodis, A., Rzajeva, T., Kalējs, V. R., Smilga, T. M., & Pūpola, M. (2023). Crossed Cerebellar Diaschisis in a Status Epilepticus Patient with Stroke-Mimicking Changes: A Case Report with Suboptimal Outcome. American Journal of Case Reports. https://doi.org/10.12659/ajcr.942715

Vancouver

Balodis A, Rzajeva T, Kalējs VR, Smilga TM, Pūpola M. Crossed Cerebellar Diaschisis in a Status Epilepticus Patient with Stroke-Mimicking Changes: A Case Report with Suboptimal Outcome. American Journal of Case Reports. 2023. doi:10.12659/ajcr.942715

BibTeX
@article{Balodis2023,
  author = {Balodis, Arturs and Rzajeva, Tatjana and Kalējs, Verners Roberts and Smilga, Toms Mārtiņš and Pūpola, Marta},
  title = {Crossed Cerebellar Diaschisis in a Status Epilepticus Patient with Stroke-Mimicking Changes: A Case Report with Suboptimal Outcome},
  journal = {American Journal of Case Reports},
  year = {2023},
  doi = {10.12659/ajcr.942715}
}
Kostenlos starten →