Radiation dose and factors related to exceeding the diagnostic reference level in 496 transnasal ileus tube placement procedures from the REX-GI study
The British Journal of Radiology · 2023
DOI: 10.1259/bjr.20230086 ↗Kurz gefasst
Fachartikel in der Zeitschrift The British Journal of Radiology, 2023. Verfasst von Koji Nagaike und 17 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology and Hepatology, Suita Municipal Hospital, Suita, Osaka, Japan. Hauptthemen laut MEDLINE: Intestinal Obstruction, Ileus. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Objective
We aimed to examine the factors contributing to radiation exposure exceeding the DRL of the transnasal ileus tube placement in this post hoc analysis from the cohort of the REX-GI study.
Methods
Patients with transnasal ileus tubes were enrolled in the rex-gi study from may 2019 to december 2020. We investigated the endoscope insertion time (min), procedure time (min), tube insertion length (cm), fluoroscopy time (FT: min), air kerma at the patient entrance reference point (K a.r : mGy), and air kerma–area product (P KA : Gycm 2 ). The third quartile value of the P KA value was calculated as the diagnostic reference level (DRL) value. We explored the factors associated with radiation exposure exceeding the DRL.
Results
In the REX-GI study, 496 patients who underwent transnasal ileus tube placement were enrolled. The median age of the patients was 71 years. The median endoscopy insertion time, procedure time, and tube insertion length were 6 min, 20 min, and 170 cm, respectively. The third quartile/median FT, K a.r , and P KA were 18/11.9 min, 99.2/54.4 mGy, and 46.9/28 Gycm 2 , respectively. The third quartile value of P KA (47 Gycm 2 ) was set as the DRL value. There were differences in distribution by the hospital. Compared with procedures under the DRL, the FT (19 vs 10 min), procedure time (25 vs 18 min), and tube insertion length (185 vs 165 cm) were significantly longer for procedures above the DRL.
Conclusion
We report the DRL for transnasal ileus tube placement in Japan. A longer procedure time and tube insertion length may be associated with DRL exceedance. Advances in knowledge: Transnasal ileus tube placement under fluoroscopy guidance is a standard clinical procedure for bowel obstruction. However, the appropriate radiation dose level has not yet been established. We report the (DRL) for transnasal ileus tube placement in Japan. A longer procedure time and tube insertion length may be associated with DRL exceedance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Gastroenterology and Hepatology, Suita Municipal Hospital, Suita, Osaka, Japan.
- Department of Gastroenterology and Internal Medicine, Hayashi Clinic, Suita, Osaka, Japan.
- Department of Gastroenterology, Toyonaka Municipal Hospital, Toyonaka, Osaka, Japan.
- Department of Gastroenterology and Hepatology, Osaka General Medical Center, Osaka, Osaka, Japan.
- Department of Gastroenterology, Tonan Hospital, Sapporo, Hokkaido, Japan.
- Department of Gastroenterology and Hepatology, Kansai Rosai Hospital, Amagasaki, Hyogo, Japan.
ORCID-Profile: Tsutomu Nishida
Zitieren
APA
Nagaike, K., Hayashi, S., Yakushijin, T., Yamamoto, M., Sumiyoshi, T., Yamaguchi, S., Tamaru, Y., Yamada, T., Tsumura, H., Nakai, Y., Doyama, H., Maetani, I., Takagi, T., Asai, S., Matsubara, K., Takenaka, M., Hosono, M., & Nishida, T. (2023). Radiation dose and factors related to exceeding the diagnostic reference level in 496 transnasal ileus tube placement procedures from the REX-GI study. The British Journal of Radiology. https://doi.org/10.1259/bjr.20230086
Vancouver
Nagaike K, Hayashi S, Yakushijin T, Yamamoto M, Sumiyoshi T, Yamaguchi S, et al. Radiation dose and factors related to exceeding the diagnostic reference level in 496 transnasal ileus tube placement procedures from the REX-GI study. The British Journal of Radiology. 2023. doi:10.1259/bjr.20230086
BibTeX
@article{Nagaike2023,
author = {Nagaike, Koji and Hayashi, Shiro and Yakushijin, Takayuki and Yamamoto, Masashi and Sumiyoshi, Tetsuya and Yamaguchi, Shinjiro and Tamaru, Yuzuru and Yamada, Takuya and Tsumura, Hidetaka and Nakai, Yousuke and Doyama, Hisashi and Maetani, Iruru and Takagi, Tadayuki and Asai, Satoshi and Matsubara, Kosuke and Takenaka, Mamoru and Hosono, Makoto and Nishida, Tsutomu},
title = {Radiation dose and factors related to exceeding the diagnostic reference level in 496 transnasal ileus tube placement procedures from the REX-GI study},
journal = {The British Journal of Radiology},
year = {2023},
doi = {10.1259/bjr.20230086}
}
EUVIMED