An automatic fresh rib fracture detection and positioning system using deep learning
The British Journal of Radiology · 2023
DOI: 10.1259/bjr.20221006 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift The British Journal of Radiology, 2023. Verfasst von Ning Li und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Fushun Central Hospital of Liaoning Province, Fushun, Liaoning Province, China. Hauptthemen laut MEDLINE: Rib Fractures, Deep Learning. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Objective
To evaluate the performance and robustness of a deep learning-based automatic fresh rib fracture detection and positioning system (FRF-DPS).
Methods
CT scans of 18,172 participants admitted to eight hospitals from June 2009 to March 2019 were retrospectively collected. Patients were divided into development set (14,241), multicenter internal test set (1612), and external test set (2319). In internal test set, sensitivity, false positives (FPs) and specificity were used to assess fresh rib fracture detection performance at the lesion- and examination-levels. In external test set, the performance of detecting fresh rib fractures by radiologist and FRF-DPS were evaluated at lesion, rib, and examination levels. Additionally, the accuracy of FRF-DPS in rib positioning was investigated by the ground-truth labeling.
Results
In multicenter internal test set, FRF-DPS showed excellent performance at the lesion- (sensitivity: 0.933 [95%CI, 0.916–0.949], FPs: 0.50 [95%CI, 0.397–0.583]) and examination-level. In external test set, the sensitivity and FPs at the lesion-level of FRF-DPS (0.909 [95%CI, 0.883–0.926], p < 0.001; 0.379 [95%CI, 0.303–0.422], p = 0.001) were better than the radiologist (0.789 [95%CI, 0.766–0.807]; 0.496 [95%CI, 0.383–0.571]), so were the rib- and patient-levels. In subgroup analysis of CT parameters, FRF-DPS were robust (0.894–0.927). Finally, FRF-DPS(0.997 [95%CI, 0.992–1.000], p < 0.001) is more accurate than radiologist (0.981 [95%CI, 0.969–0.996]) in rib positioning and takes 20 times less time.
Conclusion
FRF-DPS achieved high detection rate of fresh rib fractures with low FP values, and precise positioning of ribs, thus can be used in clinical practice to improve the detection rate and work efficiency. Advances in knowledge: We developed the FRF-DPS system which can detect fresh rib fractures and rib position, and evaluated by a large amount of multicenter data.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Radiology, Fushun Central Hospital of Liaoning Province, Fushun, Liaoning Province, China.
- Deepwise Artificial Intelligence (AI) Lab, Deepwise Inc., Beijing, China.
Zitieren
APA
Li, N., Wu, Z., Jiang, C., Sun, L., Li, B., Guo, J., Liu, F., Zhou, Z., Qin, H., Tan, W., & Tian, L. (2023). An automatic fresh rib fracture detection and positioning system using deep learning. The British Journal of Radiology. https://doi.org/10.1259/bjr.20221006
Vancouver
Li N, Wu Z, Jiang C, Sun L, Li B, Guo J, et al. An automatic fresh rib fracture detection and positioning system using deep learning. The British Journal of Radiology. 2023. doi:10.1259/bjr.20221006
BibTeX
@article{Li2023,
author = {Li, Ning and Wu, Zhe and Jiang, Chao and Sun, Lulu and Li, Bingyao and Guo, Jun and Liu, Feng and Zhou, Zhen and Qin, Haibo and Tan, Weixiong and Tian, Lufeng},
title = {An automatic fresh rib fracture detection and positioning system using deep learning},
journal = {The British Journal of Radiology},
year = {2023},
doi = {10.1259/bjr.20221006}
}