Atraumatic versus cutting needles in fluoroscopic lumbar puncture
The British Journal of Radiology · 2023
DOI: 10.1259/bjr.20220993 ↗Kurz gefasst
Fachartikel in der Zeitschrift The British Journal of Radiology, 2023. Verfasst von Dana Yen Lin Lee und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Alfred Health, Melbourne, Victoria, Australia. Hauptthemen laut MEDLINE: Spinal Puncture, Post-Dural Puncture Headache. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Objectives
Atraumatic needles are known to reduce complication rates of blind lumbar punctures (LP), however, their use in fluoroscopically guided LP is less studied. This study assessed the comparative difficulty of performing fluoroscopic lumbar puncture with atraumatic needles.
Methods
Single-centre retrospective case-control study comparing atraumatic and conventional or “cutting” needles using fluoroscopic time and radiation dose (Dose Area Product or DAP) as surrogate markers. Patients were assessed from two comparable eight-month periods before and after a policy change to primary use of atraumatic needles.
Results
105 procedures with a cutting needle were performed in the group prior to the policy change. Median fluoroscopy time was 48 sec and median DAP was 3.14. Of 102 procedures performed in the group after the policy change, 99 were performed with an atraumatic needle and three with a cutting needle after initial attempt with an atraumatic needle. Median fluoroscopy time was 41 sec and median DAP was 3.28. The mean number of attempts was 1.02 in the cutting needle group and 1.05 in the atraumatic needle group. There was no significant difference in median fluoroscopy time, median DAP, or mean number of attempts.
Conclusion
Fluoroscopic screening time, DAP and mean number of attempts were not significantly increased with primary use of atraumatic needles for LP. Use of atraumatic needles should be considered in fluoroscopic LP given the lower complication rates. Advances in knowledge: This study provides new data showing that the use of atraumatic needles does not increase the difficulty of fluoroscopically guided LP.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Radiology, Alfred Health, Melbourne, Victoria, Australia.
- Department of Surgery, Monash University Central Clinical School, Melbourne, Victoria, Australia.
- National Trauma Research Institute, Melbourne, Victoria, Australia.
ORCID-Profile: Dana Yen Lin Lee, Matthew Lukies
Zitieren
APA
Lee, D. Y. L., Clements, W., & Lukies, M. (2023). Atraumatic versus cutting needles in fluoroscopic lumbar puncture. The British Journal of Radiology. https://doi.org/10.1259/bjr.20220993
Vancouver
Lee DYL, Clements W, Lukies M. Atraumatic versus cutting needles in fluoroscopic lumbar puncture. The British Journal of Radiology. 2023. doi:10.1259/bjr.20220993
BibTeX
@article{Lee2023,
author = {Lee, Dana Yen Lin and Clements, Warren and Lukies, Matthew},
title = {Atraumatic versus cutting needles in fluoroscopic lumbar puncture},
journal = {The British Journal of Radiology},
year = {2023},
doi = {10.1259/bjr.20220993}
}
EUVIMED