Fachartikel in der Zeitschrift The British Journal of Radiology, 2023. Verfasst von Stephanie Tina Sauer und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, OberdürrbacherStraße, Würzburg, Germany. Hauptthemen laut MEDLINE: Mammography, Breast Neoplasms. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Objectives
Digital breast tomosynthesis (DBT) can provide additional information over mammography, albeit at the cost of prolonged reading time. This study retrospectively investigated the impact of reading enhanced synthetic 6 mm slabs instead of standard 1 mm slices on interpretation time and readers performance in a diagnostic assessment centre.
Methods
Three radiologists (R1-3; 6/4/2 years of breast imaging experience) reviewed 111 diagnostic DBT examinations. Two datasets were interpreted independently for each patient, with one set containing artificial-intelligence-enhanced synthetic 6 mm slabs with 3 mm overlap, while the other set comprised standard 1 mm slices. Blinded to histology and follow-up, readers noted individual BIRADS categories and diagnostic confidence while reading time was recorded. Among the 111 examinations, 70 findings were histopathologically correlated including 56 malignancies.
Results
No significant difference was found between BIRADS categories assigned based on 6 mm vs 1 mm datasets (p ≥ 0.317). Diagnostic accuracy was comparable for 6 mm and 1 mm readings (R1: 87.0% vs 87.0%; R2: 86.1% vs 87.0%; R3: 80.0% vs 84.4%; p ≥ 0.125) with high interrater agreement (intraclass correlation coefficient 0.848 vs 0.865). One reader reported higher confidence with 1 mm slices (R1: p = 0.033). Reading time was substantially shorter when interpreting 6 mm slabs compared to 1 mm slices (R1: 33.5 vs 46.2; R2: 49.1 vs 64.8; R3: 39.5 vs 67.2 sec; all p < 0.001).
Conclusions
Artificial-intelligence-enhanced synthetic 6 mm slabs allow for substantial interpretation time reduction in diagnostic DBT without a decrease in reader accuracy. Advances in knowledge: A simplified slab-only protocol instead of 1 mm slices may offset the higher reading time without a loss of diagnosis-relevant image information in first and second readings. Further evaluations are required regarding workflow implications, particularly in screening settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, OberdürrbacherStraße, Würzburg, Germany.
- Department of Obstetrics and Gynaecology, University Hospital Würzburg, Josef-Schneider-Straße , Würzburg, Germany.
ORCID-Profile: Jan-Peter Grunz
Zitieren
APA
Sauer, S. T., Christner, S. A., Kuhl, P. J., Kunz, A. S., Huflage, H., Luetkens, K. S., Schlaiß, T., Bley, T. A., & Grunz, J. P. (2023). Artificial-intelligence-enhanced synthetic thick slabs versus standard slices in digital breast tomosynthesis. The British Journal of Radiology. https://doi.org/10.1259/bjr.20220967
Vancouver
Sauer ST, Christner SA, Kuhl PJ, Kunz AS, Huflage H, Luetkens KS, et al. Artificial-intelligence-enhanced synthetic thick slabs versus standard slices in digital breast tomosynthesis. The British Journal of Radiology. 2023. doi:10.1259/bjr.20220967
BibTeX
@article{Sauer2023,
author = {Sauer, Stephanie Tina and Christner, Sara Aniki and Kuhl, Philipp Josef and Kunz, Andreas Steven and Huflage, Henner and Luetkens, Karsten Sebastian and Schlaiß, Tanja and Bley, Thorsten Alexander and Grunz, Jan-Peter},
title = {Artificial-intelligence-enhanced synthetic thick slabs versus standard slices in digital breast tomosynthesis},
journal = {The British Journal of Radiology},
year = {2023},
doi = {10.1259/bjr.20220967}
}
EUVIMED