Sinus Rhythm Maintenance After Pulsed-Field Ablation Is Associated With Improved Right Ventricular–Pulmonary Artery Coupling Without Significant Increase in Pulmonary Artery Pressure
Circulation Journal · 2026
DOI: 10.1253/circj.cj-26-0044 ↗Kurz gefasst
Fachartikel in der Zeitschrift Circulation Journal, 2026. Verfasst von Akio Chikata und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Toyama Prefectural Central Hospital. Hauptthemen laut MEDLINE: Pulmonary Artery, Atrial Fibrillation, Catheter Ablation, Arterial Pressure. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Atrial fibrillation (AF) is associated with disrupted right ventricular-pulmonary artery (RV-PA) coupling. Pulsed-field ablation (PFA) is less likely to induce an increase in pulmonary arterial pressure; however, changes in RV-PA coupling following AF ablation using PFA remain unclear. METHODS AND RESULTS: We retrospectively analyzed consecutive patients who underwent AF ablation using PFA. RV-PA coupling was assessed using the echocardiographic tricuspid annular plane systolic excursion (TAPSE) to pulmonary artery systolic pressure (PASP) ratio before and 3 months after ablation. In all, 103 patients were included in this study: 46 with paroxysmal AF (PAF) and 57 with persistent AF (PeAF), with 41 PeAF patients maintaining sinus rhythm (SR) at 3 months. The TAPSE/PASP ratio improved significantly after AF ablation using PFA in the overall cohort (mean [±SD] 0.794±0.313 vs. 0.906±0.294; P=0.009) and in PeAF patients (0.740±0.343 vs. 0.887±0.282, P=0.01); however, no significant change was observed in PAF patients (P=0.26). PASP did not increase after ablation in any group. Among PeAF patients maintaining SR at 3 months, baseline mean heart rate during AF showed a weak association with changes in the TAPSE/PASP ratio. CONCLUSIONS: AF ablation using PFA was associated with an improvement in RV-PA coupling without an increase in pulmonary arterial pressure, particularly in patients with PeAF in whom SR was maintained at 3 months.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Toyama Prefectural Central Hospital.
- Department of Cardiovascular Medicine, Kanazawa University Graduate School of Medical Science.
- Department of Pediatrics, Toyama Prefectural Central Hospital.
Zitieren
APA
Chikata, A., Kato, T., Fujita, S., Usuda, K., Maruyama, M., Otowa, K. I., Kusayama, T., Hayashi, K., & Takamura, M. (2026). Sinus Rhythm Maintenance After Pulsed-Field Ablation Is Associated With Improved Right Ventricular–Pulmonary Artery Coupling Without Significant Increase in Pulmonary Artery Pressure. Circulation Journal. https://doi.org/10.1253/circj.cj-26-0044
Vancouver
Chikata A, Kato T, Fujita S, Usuda K, Maruyama M, Otowa KI, et al. Sinus Rhythm Maintenance After Pulsed-Field Ablation Is Associated With Improved Right Ventricular–Pulmonary Artery Coupling Without Significant Increase in Pulmonary Artery Pressure. Circulation Journal. 2026. doi:10.1253/circj.cj-26-0044
BibTeX
@article{Chikata2026,
author = {Chikata, Akio and Kato, Takeshi and Fujita, Shuhei and Usuda, Kazuo and Maruyama, Michiro and Otowa, Kan-Ichi and Kusayama, Takashi and Hayashi, Kenshi and Takamura, Masayuki},
title = {Sinus Rhythm Maintenance After Pulsed-Field Ablation Is Associated With Improved Right Ventricular–Pulmonary Artery Coupling Without Significant Increase in Pulmonary Artery Pressure},
journal = {Circulation Journal},
year = {2026},
doi = {10.1253/circj.cj-26-0044}
}
EUVIMED