Impact of Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stents in Percutaneous Coronary Intervention for Hemodialysis Patients
Circulation Journal · 25.07.2025 · 89 (8) · 1113-1120
DOI: 10.1253/circj.cj-24-0589 ↗Kurz gefasst
Fachartikel in der Zeitschrift Circulation Journal, erschienen am 25.07.2025. Verfasst von Narumi Taninobu und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Kurashiki Central Hospital. Hauptthemen laut MEDLINE: Drug-Eluting Stents, Renal Dialysis, Sirolimus, Percutaneous Coronary Intervention. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Hemodialysis (HD) is associated with adverse cardiovascular events after percutaneous coronary intervention (PCI). Although the ultrathin strut biodegradable polymer sirolimus-eluting stent (ultrathin strut BP-SES) has had better results in patients undergoing PCI compared with other drug-eluting stents (DES), its usefulness in HD patients is unknown. METHODS AND RESULTS: This study involved 286 lesions in 162 HD patients who underwent PCI with a DES between January 2018 and June 2022. The incidence of clinically driven target lesion revascularization (TLR), target vessel failure (TVF: cardiac death, target vessel MI and clinically driven target vessel revascularization [TVR]) was assessed. During a median 636 days, clinically driven TLR occurred in 32 lesions. Clinically driven TLR at 2 years was significantly lower in the ultrathin strut BP-SES group than in the other DES group (2.9% vs. 17.3%, log-rank P=0.028). TVF occurred in 43 patients. The cumulative incidence of TVF was not different between two groups; however, clinically driven TVR was significantly lower in patients treated with the ultrathin strut BP-SES than with other DES (4.5% vs. 25.7%, log-rank P=0.027). In the quantitative coronary angiography analysis, late lumen loss at follow-up was significantly smaller in the ultrathin strut BP-SES group (0.13±0.40 vs. 0.67±1.02 mm, P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Cardiology, Kurashiki Central Hospital.
Zitieren
APA
Taninobu, N., Kubo, S., Oka, S., Nishiura, N., Sasaki, K., Matsushita, S., Mushiake, K., Shima, Y., Ikuta, A., Osakada, K., Sawayama, Y., Tada, T., Fuku, Y., Tanaka, H., & Kadota, K. (2025). Impact of Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stents in Percutaneous Coronary Intervention for Hemodialysis Patients. Circulation Journal, 89(8), 1113-1120. https://doi.org/10.1253/circj.cj-24-0589
Vancouver
Taninobu N, Kubo S, Oka S, Nishiura N, Sasaki K, Matsushita S, et al. Impact of Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stents in Percutaneous Coronary Intervention for Hemodialysis Patients. Circulation Journal. 2025;89(8):1113-1120. doi:10.1253/circj.cj-24-0589
BibTeX
@article{Taninobu2025,
author = {Taninobu, Narumi and Kubo, Shunsuke and Oka, Satoki and Nishiura, Naoki and Sasaki, Kenta and Matsushita, Shunsuke and Mushiake, Kazunori and Shima, Yuki and Ikuta, Akihiro and Osakada, Kohei and Sawayama, Yuichi and Tada, Takeshi and Fuku, Yasushi and Tanaka, Hiroyuki and Kadota, Kazusige},
title = {Impact of Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stents in Percutaneous Coronary Intervention for Hemodialysis Patients},
journal = {Circulation Journal},
year = {2025},
volume = {89},
number = {8},
pages = {1113--1120},
doi = {10.1253/circj.cj-24-0589}
}
EUVIMED