EUVIMEDEUVIMED entdecken
Crossref

Early Outcomes Following Transcatheter Closure With the Amplatzer Vascular Plug and Duct Occluder for Mitral Paravalvular Leak in Japanese Patients

Hiroki Niikura, Kenji Makino, Norihiro Kogame, Go Hashimoto, Yoshiyuki Yazaki, Hidehiko Hara

Circulation Journal · 2025

DOI: 10.1253/circj.cj-24-0544 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Circulation Journal, 2025. Verfasst von Hiroki Niikura und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Toho University Ohashi Medical Center. Hauptthemen laut MEDLINE: Septal Occluder Device, Cardiac Catheterization, Mitral Valve, Mitral Valve Insufficiency. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Transcatheter closure of paravalvular leak (PVL) has become an established treatment for patients at prohibitive surgical risk. However, few studies have examined the feasibility of transcatheter closure using Amplatzer occluders in Japanese patients with mitral PVL. METHODS AND RESULTS: Twelve patients (mean [±SD] age 78±7 years) with heart failure, hemolytic anemia, or both after surgical mitral prosthetic valve replacement (mechanical valve, 75%) underwent transcatheter PVL closure with Amplatzer Vascular Plug II (AVP-II)/Amplatzer Duct Occluder II (ADO-II) between 2014 and 2021 at Toho University Ohashi Medical Center. We examined procedural, in-hospital, 30-day, and 1-year outcomes. All procedures were performed under general anesthesia using an antegrade transseptal approach, and the procedures were successful in all cases. The mean (±SD) number of Amplatzer occluders deployment per patient was 2.9±1.1, and in 2 patients the combined use of ADO-II was required. The mitral PVL grade decreased notably from 3+ to 1+, with residual PVL being mild or absent in 9 patients. There were no all-cause mortalities, major adverse events, or device-related complications at the 30-day follow-up. At 1 year, all-cause mortality was 16.7% and 3 (25%) patients required reintervention because of the recurrence of clinical symptoms. CONCLUSIONS: Our findings suggest that transcatheter PVL closure with AVP-II/ADO-II can be feasible and safe in Japanese patients with mitral PVL, leading to satisfactory early clinical outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Septal Occluder DeviceCardiac CatheterizationMitral ValveMitral Valve InsufficiencyHeart Valve Prosthesis ImplantationHumansAgedMaleFemaleAged, 80 and overJapanTreatment OutcomeRetrospective StudiesHeart Valve ProsthesisEast Asian People

Stichwörter der Autor:innen

Amplatzer Vascular Plug IIMitral valve surgeryParavalvular leakTranscatheter paravalvular leak closure

Autor:innen und Institutionen

  • Division of Cardiology, Toho University Ohashi Medical Center.

Zitieren

APA

Niikura, H., Makino, K., Kogame, N., Hashimoto, G., Yazaki, Y., & Hara, H. (2025). Early Outcomes Following Transcatheter Closure With the Amplatzer Vascular Plug and Duct Occluder for Mitral Paravalvular Leak in Japanese Patients. Circulation Journal. https://doi.org/10.1253/circj.cj-24-0544

Vancouver

Niikura H, Makino K, Kogame N, Hashimoto G, Yazaki Y, Hara H. Early Outcomes Following Transcatheter Closure With the Amplatzer Vascular Plug and Duct Occluder for Mitral Paravalvular Leak in Japanese Patients. Circulation Journal. 2025. doi:10.1253/circj.cj-24-0544

BibTeX
@article{Niikura2025,
  author = {Niikura, Hiroki and Makino, Kenji and Kogame, Norihiro and Hashimoto, Go and Yazaki, Yoshiyuki and Hara, Hidehiko},
  title = {Early Outcomes Following Transcatheter Closure With the Amplatzer Vascular Plug and Duct Occluder for Mitral Paravalvular Leak in Japanese Patients},
  journal = {Circulation Journal},
  year = {2025},
  doi = {10.1253/circj.cj-24-0544}
}
Kostenlos starten →