Five-Year Transcatheter Aortic Valve Replacement Outcomes in Chronic Hemodialysis vs. Non-Hemodialysis Patients Using Balloon-Expandable Devices
Circulation Journal · 2024
DOI: 10.1253/circj.cj-24-0050 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Circulation Journal, 2024. Verfasst von Isamu Mizote und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Osaka University Graduate School of Medicine. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Renal Dialysis. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Based on the results of a clinical trial in Japan, transcatheter aortic valve replacement (TAVR) for hemodialysis (HD) patients gained approval; however, mid-term TAVR outcomes and transcatheter aortic valve (TAV) durability in HD patients remain unexplored. METHODS AND RESULTS: We analyzed background, procedural, in-hospital outcome, and follow-up data for 101 HD patients and 494 non-HD patients who underwent TAVR using balloon-expandable valves (SAPIEN XT or SAPIEN 3) retrieved from Osaka University Hospital TAVR database. Periprocedural mortality and TAVR-related complications were comparable between HD and non-HD patients. However, Kaplan-Meier analysis revealed that HD patients had significantly lower survival rates (log-rank test, P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Medicine, Osaka University Graduate School of Medicine.
- Department of Cardiovascular Surgery, Osaka University Graduate School of Medicine.
Zitieren
APA
Mizote, I., Nakamura, D., Maeda, K., Dohi, T., Shimamura, K., Kawamura, A., Yamashita, K., Matsuhiro, Y., Kosugi, S., Sugae, H., Takeda, Y., & Sakata, Y. (2024). Five-Year Transcatheter Aortic Valve Replacement Outcomes in Chronic Hemodialysis vs. Non-Hemodialysis Patients Using Balloon-Expandable Devices. Circulation Journal. https://doi.org/10.1253/circj.cj-24-0050
Vancouver
Mizote I, Nakamura D, Maeda K, Dohi T, Shimamura K, Kawamura A, et al. Five-Year Transcatheter Aortic Valve Replacement Outcomes in Chronic Hemodialysis vs. Non-Hemodialysis Patients Using Balloon-Expandable Devices. Circulation Journal. 2024. doi:10.1253/circj.cj-24-0050
BibTeX
@article{Mizote2024,
author = {Mizote, Isamu and Nakamura, Daisuke and Maeda, Koichi and Dohi, Tomoharu and Shimamura, Kazuo and Kawamura, Ai and Yamashita, Kizuku and Matsuhiro, Yutaka and Kosugi, Shumpei and Sugae, Hiroki and Takeda, Yasuharu and Sakata, Yasushi},
title = {Five-Year Transcatheter Aortic Valve Replacement Outcomes in Chronic Hemodialysis vs. Non-Hemodialysis Patients Using Balloon-Expandable Devices},
journal = {Circulation Journal},
year = {2024},
doi = {10.1253/circj.cj-24-0050}
}
EUVIMED