EUVIMEDEUVIMED entdecken
Crossref

Occurrence of Benzotriazole-Based UV Absorbers in Japanese Household Dust

Taichi Yoshitomi, Iwaki Nishi, Fumi Nakano, Hitoshi Uemura, Maiko Tahara, Shinobu Sakai

BPB Reports · 2026 · 9 (1) · 8-14

DOI: 10.1248/bpbreports.9.1_8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift BPB Reports, 2026. Verfasst von Taichi Yoshitomi und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Benzotriazole-based ultraviolet absorbers (BUVs) are widely used in polymers due to their high thermal and photo stability. However, their environmental persistence and bioaccumulation potential have raised concerns, and some have become subject to regulation. BUVs have been detected in water, air, road dust, biota, and indoor products such as plastics and paints. They have also been frequently found in household dust (HD), which accumulates semi-volatile organic compounds; however, no studies to date have investigated the presence of BUVs in Japanese HD. This study established an LC–MS/MS method with atmospheric pressure chemical ionization (APCI) to quantify eight BUVs in HD and evaluate their occurrence in Japanese residences. Here, eight BUVs were selected for analysis, including UV-320—classified as a Class I specified chemical substance under Japan’s Chemical Substances Control Law—and UV-328, newly listed in 2024. Sample preparation was optimized by evaluating six solid-phase extraction methods, among which basic alumina-based cartridges demonstrated selective BUV retention. High recoveries ranging from 86.9 to 100% were achieved using a back-flush elution approach. Using the developed method, HD samples collected in 2023 and 2024 were analyzed. Six compounds, excluding UV-320 and UV-PS, were detected in 100% of the samples. Although the maximum and minimum concentrations varied considerably between the two years, the median values and detection frequencies showed generally consistent trends. These findings reveal the contamination status of BUVs in Japanese HD and demonstrate that the developed APCI–LC–MS/MS method is a reliable approach for indoor pollution monitoring.

Zitieren

APA

Yoshitomi, T., Nishi, I., Nakano, F., Uemura, H., Tahara, M., & Sakai, S. (2026). Occurrence of Benzotriazole-Based UV Absorbers in Japanese Household Dust. BPB Reports, 9(1), 8-14. https://doi.org/10.1248/bpbreports.9.1_8

Vancouver

Yoshitomi T, Nishi I, Nakano F, Uemura H, Tahara M, Sakai S. Occurrence of Benzotriazole-Based UV Absorbers in Japanese Household Dust. BPB Reports. 2026;9(1):8-14. doi:10.1248/bpbreports.9.1_8

BibTeX
@article{Yoshitomi2026,
  author = {Yoshitomi, Taichi and Nishi, Iwaki and Nakano, Fumi and Uemura, Hitoshi and Tahara, Maiko and Sakai, Shinobu},
  title = {Occurrence of Benzotriazole-Based UV Absorbers in Japanese Household Dust},
  journal = {BPB Reports},
  year = {2026},
  volume = {9},
  number = {1},
  pages = {8--14},
  doi = {10.1248/bpbreports.9.1_8}
}
Kostenlos starten →