Fachartikel in der Zeitschrift Biological and Pharmaceutical Bulletin, 2025. Verfasst von Aya Torii-Goto und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmacy, College of Pharmacy, Kinjo Gakuin University, 2-1723 Omori, Moriyama-ku, Nagoya 463-8521, Japan. Hauptthemen laut MEDLINE: Blood Glucose Self-Monitoring, Blood Glucose, Prediabetic State. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We examined whether the glucose levels and awareness of individuals without diabetes changed after using a sensor-based intermittently scanned continuous glucose monitoring (isCGM) system in their daily lives. Japanese individuals without a diabetes diagnosis wore the isCGM system while maintaining a normal lifestyle during the baseline period. A certified diabetes educator coached them on how to improve their lifestyle based on information from sensor data, food journals, and body composition. The participants subsequently consumed a specific diet, exercised for 2 months, and wore a new sensor after the intervention period. A total of 36 Japanese participants were eligible for analysis in this study. The time above range and the area under the curve did not change between before and after the intervention in overall participants. The visual analogue scale scores significantly increased from before to after the intervention in the overall participants. Stratified analysis was performed by dividing the participants into 18 control participants (glycated hemoglobin level

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood Glucose Self-MonitoringBlood GlucosePrediabetic StateHumansJapanFemaleMaleMiddle AgedAgedRisk ManagementAdultGlycated HemoglobinLife StyleDiabetes Mellitus, Type 2Continuous Glucose Monitoring

Stichwörter der Autor:innen

diabetesintermittently scanned continuous glucose monitoring systemprediabetesrisk management

Substanzen

Blood GlucoseGlycated Hemoglobin

Autor:innen und Institutionen

  • Department of Pharmacy, College of Pharmacy, Kinjo Gakuin University, 2-1723 Omori, Moriyama-ku, Nagoya 463-8521, Japan.
  • Nagoya City Pharmacist Association, 3-4-2 Marunouchi, Naka-ku, Nagoya 460-0002, Japan.
  • Department of Advanced Cardiovascular Therapeutics, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan.

Zitieren

APA

Torii-Goto, A., Fukaya, S., Amioka, K., Shibata, R., & Yoshikawa, M. (2025). Usefulness of an Intermittently Scanned Continuous Glucose Monitoring System for Risk Management of Individuals without Diabetes in Japan. Biological and Pharmaceutical Bulletin. https://doi.org/10.1248/bpb.b24-00340

Vancouver

Torii-Goto A, Fukaya S, Amioka K, Shibata R, Yoshikawa M. Usefulness of an Intermittently Scanned Continuous Glucose Monitoring System for Risk Management of Individuals without Diabetes in Japan. Biological and Pharmaceutical Bulletin. 2025. doi:10.1248/bpb.b24-00340

BibTeX
@article{ToriiGoto2025,
  author = {Torii-Goto, Aya and Fukaya, Seiji and Amioka, Katsuo and Shibata, Rei and Yoshikawa, Masae},
  title = {Usefulness of an Intermittently Scanned Continuous Glucose Monitoring System for Risk Management of Individuals without Diabetes in Japan},
  journal = {Biological and Pharmaceutical Bulletin},
  year = {2025},
  doi = {10.1248/bpb.b24-00340}
}
Kostenlos starten →