Emulating the influence of exoskeleton stiffness on primary afferent feedback in rat isolated muscle-tendon unit
Journal of Experimental Biology · 2026
DOI: 10.1242/jeb.252345 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Experimental Biology, 2026. Verfasst von Amro A Alshareef und 5 weiteren Autor:innen. Beteiligte Einrichtung: Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA. Hauptthemen laut MEDLINE: Muscle, Skeletal, Tendons, Exoskeleton Device, Proprioception. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Science Foundation, National Institute of Child Health and Human Development.
Abstract (Originalsprache)
Exoskeletons assist and augment movement, but their effects on proprioceptive feedback remain poorly understood due to challenges in making direct measures of sensory signals in humans. Here, we leveraged a benchtop animal model to explore how mechanical context akin to an elastic exoskeleton operating on a human lower limb joint influences primary muscle spindle firing. In an anesthetized rat preparation, we applied controlled stretches to the medial gastrocnemius with engineered springs (0–0.5 N/mm) in parallel to the muscle-tendon unit (MTU) while modulating muscle activation to maintain overall system stiffness. Fascicle length was measured with sonomicrometry, force and MTU length with a servo motor, and spindle instantaneous firing rate (IFR) using dorsal root recordings. Trading off increases in exoskeleton stiffness with reductions in muscle activation decreased biological muscle force (3.1±0.6 N to 1.6±0.6 N, p<0.001) and stiffness (4.4±1.5 N/mm to 2.3±1.3 N/mm, p<0.01), and increased fascicle length (7.9±1.3 mm to 8.3±1.5 mm, p<0.005). We found significant correlations between spindle firing and each independent fascicle dynamics factor we investigated (p<0.005). Thus, parallel stiffness modified muscle fascicle dynamics but did not alter spindle firing, possibly due to internal trade-offs in the salient fascicle dynamics that drive spindle behavior. Leveraging in-situ experiments that enable monitoring of afferent feedback in complex mechanical contexts such as added parallel stiffness can provide a window into the effects of wearable devices on underlying sensory systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA.
- School of Biological Sciences, Georgia Institute of Technology, Atlanta, GA 30332, USA.
- Coulter Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, GA 30332, USA.
- Department of Rehabilitation Medicine, Emory University, Atlanta, GA 30332, USA.
ORCID-Profile: Amro A Alshareef, Paul Nardelli, Timothy C Cope, Lena H Ting, Gregory S Sawicki
Förderung
- Eunice Kennedy Shriver National Institute of Child Health and Human Development
- National Science Foundation
- National Institute of Child Health and Human Development
- Georgia Institute of Technology
Zitieren
APA
Alshareef, A. A., Nardelli, P., Simha, S. N., Cope, T. C., Ting, L. H., & Sawicki, G. S. (2026). Emulating the influence of exoskeleton stiffness on primary afferent feedback in rat isolated muscle-tendon unit. Journal of Experimental Biology. https://doi.org/10.1242/jeb.252345
Vancouver
Alshareef AA, Nardelli P, Simha SN, Cope TC, Ting LH, Sawicki GS. Emulating the influence of exoskeleton stiffness on primary afferent feedback in rat isolated muscle-tendon unit. Journal of Experimental Biology. 2026. doi:10.1242/jeb.252345
BibTeX
@article{Alshareef2026,
author = {Alshareef, Amro A and Nardelli, Paul and Simha, Surabhi N and Cope, Timothy C and Ting, Lena H and Sawicki, Gregory S},
title = {Emulating the influence of exoskeleton stiffness on primary afferent feedback in rat isolated muscle-tendon unit},
journal = {Journal of Experimental Biology},
year = {2026},
doi = {10.1242/jeb.252345}
}
EUVIMED