Dive-by-dive variation in the diving respiratory air volume of southern elephant seals ( Mirounga leonina )
Journal of Experimental Biology · 15.05.2025 · 228 (10)
DOI: 10.1242/jeb.249659 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Experimental Biology, online erschienen am 23.05.2025. Verfasst von George Sato und 3 weiteren Autor:innen. Beteiligte Einrichtung: Sea Mammal Research Unit, University of St Andrews, St Andrews KY16 8LB, Scotland, UK. Hauptthemen laut MEDLINE: Diving, Seals, Earless, Respiration. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Office of Naval Research, Institut Paul Emile Victor, Carnegie Trust for the Universities of Scotland.
Abstract (Originalsprache)
The role of diving respiratory air volume (DRAV) in deep-diving phocid seals remains poorly understood, largely because of the lack of methods for measuring DRAV in free-ranging divers that exhale before diving. We developed a method to estimate DRAV using a hydrodynamic glide model applied to descent glides recorded using multi-sensor data loggers. We estimated dive-by-dive DRAV for six negatively buoyant female southern elephant seals (Mirounga leonina). During shallow descent glides, rapid compression of DRAV influenced net buoyancy and gliding speed, making this phase suitable for estimating DRAV. Our results revealed dive-by-dive variation in DRAV, which was positively correlated with root mean square (RMS) sway acceleration (a proxy for per-stroke effort) and the depth at which gliding began during the initial descent. DRAV increased with both tissue density and maximum dive depth, suggesting that seals adjusted their DRAV to stay closer to neutral buoyancy through their dives. However, the observed level of adjustment did not result in neutral buoyancy at half of the maximum dive depth, as predicted to minimise round-trip locomotion costs. Instead, the seals typically adjusted DRAV to reach neutral buoyancy at ∼30 m depth, <10% of their mean maximum dive depth. This indicates that strong negative tissue density imposes transit costs that cannot be fully compensated for by DRAV adjustment alone. Future work should explore whether other breath-hold divers show similar patterns of DRAV adjustment and quantify the associated physiological and ecological benefits.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sea Mammal Research Unit, University of St Andrews, St Andrews KY16 8LB, Scotland, UK.
- National Institute of Polar Research, Tachikawa, Tokyo 190-8518, Japan.
- CNRS Centre of Biology Studies of Chizé, 79360 Villiers-en-Bois, France.
ORCID-Profile: George Sato, Taiki Adachi, Christophe Guinet, Patrick Miller
Förderung
- Office of Naval Research
- Institut Paul Emile Victor
- Carnegie Trust for the Universities of Scotland
- University of St Andrews
Zitieren
APA
Sato, G., Adachi, T., Guinet, C., & Miller, P. (2025). Dive-by-dive variation in the diving respiratory air volume of southern elephant seals ( Mirounga leonina ). Journal of Experimental Biology, 228(10). https://doi.org/10.1242/jeb.249659
Vancouver
Sato G, Adachi T, Guinet C, Miller P. Dive-by-dive variation in the diving respiratory air volume of southern elephant seals ( Mirounga leonina ). Journal of Experimental Biology. 2025;228(10). doi:10.1242/jeb.249659
BibTeX
@article{Sato2025,
author = {Sato, George and Adachi, Taiki and Guinet, Christophe and Miller, Patrick},
title = {Dive-by-dive variation in the diving respiratory air volume of southern elephant seals ( Mirounga leonina )},
journal = {Journal of Experimental Biology},
year = {2025},
volume = {228},
number = {10},
doi = {10.1242/jeb.249659}
}
EUVIMED