High-throughput mitochondrial aerobic metabolism measurement: assessing a plate-reader approach using avian blood cells
Biology Open · 15.10.2026 · 15 (10)
DOI: 10.1242/bio.062712 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biology Open, online erschienen am 19.10.2026. Verfasst von Cloe Hadjadji und 3 weiteren Autor:innen. Beteiligte Einrichtung: Swiss Ornithological Institute, Sempach, Seerose 1, CH-6206, Switzerland. Hauptthemen laut MEDLINE: Mitochondria, Blood Cells, High-Throughput Screening Assays, Birds. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 68 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Schweizerischer Nationalfonds zur Furderung der Wissenschaftlichen Forschung, Centre National de la Recherche Scientifique, Swiss National Science Foundation.
Abstract (Originalsprache)
Mitochondria power biological processes, driving interest in measuring mitochondrial aerobic metabolism to understand individual variation in performance and fitness. High-resolution respirometry (HRR) is the gold standard because of its sensitivity and versatility, but it is time-consuming and has low throughput, limiting its use in large-scale studies. We assessed the validity of a high-throughput, fluorescence-based plate reader by comparing it to HRR. In a first experiment, we measured mitochondrial respiration in blood cells from two bird species (quails and chickens) across three temperatures (hypothermia, normothermia, and hyperthermia). The two methods were moderately correlated and revealed similar species effects; however, temperature effects differed between approaches, particularly under hyperthermic conditions, indicating that the plate-reader approach is best suited for stable, normothermic conditions. In a second experiment on sex differences in quails at normothermia, the two methods agreed quantitatively for proton leak and oxidative control efficiency and qualitatively for oxidative phosphorylation, although the plate-reader estimate was marginally significant (P=0.060 versus P=0.046 for HRR). The plate reader's main limitation is its lower sensitivity and greater measurement error, which could be offset by increasing sample sizes. Following protocol optimisation for each study system, this approach may offer a useful high-throughput complement to HRR for studies prioritising larger sample sizes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Swiss Ornithological Institute, Sempach, Seerose 1, CH-6206, Switzerland.
- Department of Ecology and Evolution, University of Lausanne, Lausanne CH-1015, Switzerland.
- Université de Strasbourg, CNRS, IPHC UMR 7178, F-67000 Strasbourg, France.
- Department of Biology, University of Turku, Turku, FI-20014, Finland.
ORCID-Profile: Cloe Hadjadji, Molly Ohse, Antoine Stier, Pierre Bize
Förderung
- Schweizerischer Nationalfonds zur Furderung der Wissenschaftlichen Forschung
- Centre National de la Recherche Scientifique
- Swiss National Science Foundation
Zitieren
APA
Hadjadji, C., Ohse, M., Stier, A., & Bize, P. (2026). High-throughput mitochondrial aerobic metabolism measurement: assessing a plate-reader approach using avian blood cells. Biology Open, 15(10). https://doi.org/10.1242/bio.062712
Vancouver
Hadjadji C, Ohse M, Stier A, Bize P. High-throughput mitochondrial aerobic metabolism measurement: assessing a plate-reader approach using avian blood cells. Biology Open. 2026;15(10). doi:10.1242/bio.062712
BibTeX
@article{Hadjadji2026,
author = {Hadjadji, Cloe and Ohse, Molly and Stier, Antoine and Bize, Pierre},
title = {High-throughput mitochondrial aerobic metabolism measurement: assessing a plate-reader approach using avian blood cells},
journal = {Biology Open},
year = {2026},
volume = {15},
number = {10},
doi = {10.1242/bio.062712}
}
EUVIMED