EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Continuous measurement of oxygen consumption rate in hypoxic conditions with adherent cells using an oxygen-sensitive optode

Nick Taber, Ricardo Alva, Jacob E Wiebe, Dorcas Adewumi, Jeffrey A Stuart iD

Biology Open · 06.11.2026

DOI: 10.1242/bio.062686 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biology Open, online erschienen am 06.11.2026. Verfasst von Nick Taber und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biological Sciences, Brock University, St. Catharines, Ontario L2S 3A1, Canada. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cellular oxygen consumption rate (OCR) is a widely used readout of mitochondrial respiration and oxidative metabolism. However, many OCR assay workflows are limited by short assay durations, expensive specialized instrumentation, and reduced flexibility under controlled low-oxygen conditions. Here, we describe an in-incubator method for continuous, non-disruptive OCR measurement in adherent cell cultures using the PreSens OxoDish optical oxygen-sensing system. OCR is estimated by applying the steady-state solution of Fick's law to pericellular oxygen measurements acquired at well bottoms. This approach enables OCR monitoring over several hours to 24 hours without removing plates from a standard cell-culture incubator. Using MCF-7 breast cancer cells cultured in DMEM, we calculated basal OCR values of 20.07-32.79 amol cell−1s−1, similar to published values obtained using other methods. We also demonstrate a respiration profiling approach analogous to SeahorseXF Mito Stress Tests by quantifying OCR in parallel wells exposed to oligomycin, FCCP, or antimycin A/rotenone. Importantly, we demonstrate that the method remains functional under hypoxia (1.5% O2) without modification. Benchmarking the PreSens system against the SeahorseXF yielded values within the expected reported range. The approach we describe provides an accessible option for continuous OCR measurements in adherent cell cultures under a range of oxygen levels.

Schlagwörter

Stichwörter der Autor:innen

Adherent cell cultureHypoxiaMito stress testMitochondrial respirationOxygen consumption rateOxygen sensitive optodePericellular Oxygen

Autor:innen und Institutionen

  • Department of Biological Sciences, Brock University, St. Catharines, Ontario L2S 3A1, Canada.

ORCID-Profile: Jeffrey A Stuart

Förderung

  • Natural Sciences and Engineering Research Council of Canada

Zitieren

APA

Taber, N., Alva, R., Wiebe, J. E., Adewumi, D., & Stuart, J. A. (2026). Continuous measurement of oxygen consumption rate in hypoxic conditions with adherent cells using an oxygen-sensitive optode. Biology Open. https://doi.org/10.1242/bio.062686

Vancouver

Taber N, Alva R, Wiebe JE, Adewumi D, Stuart JA. Continuous measurement of oxygen consumption rate in hypoxic conditions with adherent cells using an oxygen-sensitive optode. Biology Open. 2026. doi:10.1242/bio.062686

BibTeX
@article{Taber2026,
  author = {Taber, Nick and Alva, Ricardo and Wiebe, Jacob E and Adewumi, Dorcas and Stuart, Jeffrey A},
  title = {Continuous measurement of oxygen consumption rate in hypoxic conditions with adherent cells using an oxygen-sensitive optode},
  journal = {Biology Open},
  year = {2026},
  doi = {10.1242/bio.062686}
}
Kostenlos starten →