EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC-ND 4.0

Camera-Based Photoplethysmography for Measuring Heartbeat Intervals During General Anesthesia

Hui-Hsuan Ke, Chien-Kun Ting, Yi-Ming Huang, Jui-Chun Hung, Pei-Yu Lai, Chang-Xing Shih, Hong-Ren Su, Wen-Chuan Kuo

Anesthesia & Analgesia · 2025

DOI: 10.1213/ane.0000000000007635 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Anesthesia & Analgesia, 2025. Verfasst von Hui-Hsuan Ke und 7 weiteren Autor:innen. Beteiligte Einrichtung: From the Institute of Biophotonics, National Yang Ming Chiao Tung University, Taipei City, Taiwan. Hauptthemen laut MEDLINE: Photoplethysmography, Anesthesia, General, Heart Rate, Monitoring, Intraoperative. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Photoplethysmography has been used to assess vital signs since the late 19th century. Recently, camera-based photoplethysmography systems have gained attention due to their noninvasive nature. However, challenges such as low perfusion, motion artifacts, and ambient light interference limit their use during surgical anesthesia. This study evaluated the efficacy of a camera-based system (FaCare) compared with that of a conventional contact monitor (GE HealthCare CARESCAPE B850 patient monitor) in measuring heartbeat intervals during various stages of surgical anesthesia. METHODS: Thirty patients undergoing video-assisted thoracic surgery were included. Data were collected using a webcam and FaCare software at 4 stages: preanesthesia, postanesthesia, postanesthesia with a shadowless lamp, and postsurgery. Six remote photoplethysmography techniques using artificial intelligence algorithms processed the data. RESULTS: The results demonstrated a high level of agreement between the FaCare and GE HealthCare monitor. Pearson correlation analysis, Bland–Altman plots, and Welch’s t test indicated that 88.1% of the heart rate correlation coefficients between the 2 devices were >0.8. Furthermore, their heartbeat interval measurements showed strong agreement in the Bland–Altman plots. FaCare showed comparable functionality, offering a noninvasive alternative suitable for operating rooms. CONCLUSIONS: This study evaluated the FaCare camera-based photoplethysmography system, integrating 6 remote photoplethysmography techniques with artificial intelligence algorithms, and compared it to a conventional contact monitor for measuring heartbeat intervals during surgical anesthesia. The results showed strong consistency between FaCare and the GE contact monitor across different anesthesia stages. These findings indicate that the noninvasive FaCare system reduces infection risks and improves patient comfort. Future research is recommended to optimize artificial intelligence algorithms, data synchronization, and sampling frequency to enhance its clinical application.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotoplethysmographyAnesthesia, GeneralHeart RateMonitoring, IntraoperativePhotographyHumansFemaleMaleMiddle AgedAgedAlgorithmsAdultPredictive Value of TestsTime FactorsReproducibility of ResultsSignal Processing, Computer-Assisted

Autor:innen und Institutionen

  • From the Institute of Biophotonics, National Yang Ming Chiao Tung University, Taipei City, Taiwan.
  • Department of Anesthesiology, School of Medicine, National Yang Ming Chiao Tung University, Taipei City, Taiwan.
  • Department of Anesthesiology, Taipei Veterans General Hospital, Taipei City, Taiwan.
  • Institute of Statistics, National Tsing Hua University, Hsinchu City, Taiwan.
  • Super Genius AItek Co. Ltd, New Taipei City, Taiwan.

Zitieren

APA

Ke, H. H., Ting, C. K., Huang, Y. M., Hung, J. C., Lai, P. Y., Shih, C. X., Su, H. R., & Kuo, W. C. (2025). Camera-Based Photoplethysmography for Measuring Heartbeat Intervals During General Anesthesia. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0000000000007635

Vancouver

Ke HH, Ting CK, Huang YM, Hung JC, Lai PY, Shih CX, et al. Camera-Based Photoplethysmography for Measuring Heartbeat Intervals During General Anesthesia. Anesthesia & Analgesia. 2025. doi:10.1213/ane.0000000000007635

BibTeX
@article{Ke2025,
  author = {Ke, Hui-Hsuan and Ting, Chien-Kun and Huang, Yi-Ming and Hung, Jui-Chun and Lai, Pei-Yu and Shih, Chang-Xing and Su, Hong-Ren and Kuo, Wen-Chuan},
  title = {Camera-Based Photoplethysmography for Measuring Heartbeat Intervals During General Anesthesia},
  journal = {Anesthesia & Analgesia},