Intraoperative PTH monitoring: does sampling site or assay generation matter?
Journal of the Endocrine Society · 06.05.2026 · 10 (6)
DOI: 10.1210/jendso/bvag109 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the Endocrine Society, online erschienen am 27.05.2026. Verfasst von Rola Kwayess und 10 weiteren Autor:innen. Beteiligte Einrichtung: Division of Endocrinology and Metabolism, Indiana University, School of Medicine, Indianapolis, IN 46202, USA. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: FIC NIH HHS.
Abstract (Originalsprache)
Context
Primary hyperparathyroidism (PHPT) is a common endocrine disorder for which minimally invasive parathyroidectomy (MIP) is the standard surgical approach. Intraoperative parathyroid hormone (IOPTH) monitoring is commonly performed using second-generation (2G) parathyroid hormone (PTH) assay.
Objective
To compare the performance of IOPTH central sampling peripheral sampling, and third-generation (3G) vs 2G assays in patients with PHPT.
Methods
This is a prospective cohort study conducted at American University of Beirut Medical Center, a tertiary hospital in Beirut, Lebanon. The study included 68 subjects with confirmed PHPT who achieved surgical cure, defined as normocalcemia at ≥6 months. IOPTH levels were measured from central and peripheral venous samples using 2G and 3G assays at various time points.
Results
The median age was 57 years, and 80% were female. One-fourth had osteoporosis or reported kidney stones. Median preoperative calcium was 10.8 mg/dL with PTH 104 pg/mL, and 82% had single-gland disease. IOPTH levels were significantly higher with 2G assay and central sampling vs 3G assay and peripheral sampling. The proportion of patients meeting the Miami criterion did not differ between assays or sampling sites. Median percentage drop in IOPTH was greater with the 3G assay compared to 2G, across all time points, at both sampling sites.
Conclusion
Although both assays similarly identified a ≥50% intraoperative decline, 3G assays demonstrated a steeper and more consistent drop, suggesting that higher assay-specific thresholds may improve decision-making. Central and peripheral sampling showed comparable predictive performance, although central sampling may allow earlier detection of PTH decline.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Endocrinology and Metabolism, Indiana University, School of Medicine, Indianapolis, IN 46202, USA.
- Calcium Metabolism and Osteoporosis Program, Department of Internal Medicine, American University of Beirut Medical Center, Beirut 1107 2020, Lebanon.
- Tulane Research Innovation for Arrhythmia Discovery (TRIAD), Tulane University School of Medicine, New Orleans, LA 70112, USA.
- American University of Beirut Medical Center, Beirut 1107 2020, Lebanon.
- University of Liege, Liege 4000, Belgium.
ORCID-Profile: Maya Rahme, Marlene Chakhtoura, Omar Kreidieh, Ghada El-Hajj Fuleihan
Förderung
- FIC NIH HHS
Zitieren
APA
Kwayess, R., Ajjour, S., Rahme, M., Assaad, M., Chakhtoura, M., Kreidieh, O., Abbas, J., Jabbour-Khoury, S., Daher, R. T., Cavalier, E., & El-Hajj Fuleihan, G. (2026). Intraoperative PTH monitoring: does sampling site or assay generation matter?. Journal of the Endocrine Society, 10(6). https://doi.org/10.1210/jendso/bvag109
Vancouver
Kwayess R, Ajjour S, Rahme M, Assaad M, Chakhtoura M, Kreidieh O, et al. Intraoperative PTH monitoring: does sampling site or assay generation matter?. Journal of the Endocrine Society. 2026;10(6). doi:10.1210/jendso/bvag109
BibTeX
@article{Kwayess2026,
author = {Kwayess, Rola and Ajjour, Sara and Rahme, Maya and Assaad, Mariam and Chakhtoura, Marlene and Kreidieh, Omar and Abbas, Jaber and Jabbour-Khoury, Samar and Daher, Rose T and Cavalier, Etienne and El-Hajj Fuleihan, Ghada},
title = {Intraoperative PTH monitoring: does sampling site or assay generation matter?},
journal = {Journal of the Endocrine Society},
year = {2026},
volume = {10},
number = {6},
doi = {10.1210/jendso/bvag109}
}
EUVIMED