Auf einen Blick

14 RCTs zeigen unter CGM eine geringe, statistisch signifikante Senkung des HbA1c bei Erwachsenen mit Typ-2-Diabetes. Für andere Glukosemarker zeigten sich ebenfalls günstige Trends.

Fragestellung

Wie wirksam sind rt-CGM und FGM bei Erwachsenen mit Typ-2-Diabetes für HbA1c und weitere Glukoseparameter?

Methode

Systematische Übersicht und Metaanalyse von RCTs; Suche in MEDLINE, Embase und Cochrane nach RCTs bei Erwachsenen mit T2DM; Bewertung der Sicherheit der Evidenz mit GRADE.

Ergebnisse

14 RCTs mit 825 Patient:innen in 9 RCTs mit rt-CGM und 822 in 5 RCTs mit FGM. HbA1c sank um etwa 0,32 %; getrennt analysiert 0,34 % für rt-CGM und 0,33 % für FGM.

Einschränkungen

Die eingeschlossenen RCTs hatten eine relativ kurze Dauer; wenige Studien berichteten klinisch wichtige Endpunkte wie UAW, Notaufnahmen oder Hospitalisierung.

Schlussfolgerung der Autor:innen

Sowohl rt-CGM als auch Flash-CGM führten bei T2DM zu geringen, statistisch signifikanten HbA1c-Abnahmen; längerfristige Studien sind nötig.

Kernaussagen

  • CGM senkte HbA1c um etwa 0,32 %
  • rt-CGM und FGM zeigten ähnliche HbA1c-Reduktionen
  • Zu klinisch wichtigen Endpunkten lagen nur wenige Daten vor

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Metaanalyse in der Zeitschrift The Journal of Clinical Endocrinology & Metabolism, online erschienen am 21.11.2023. Verfasst von Stacey Uhl und 4 weiteren Autor:innen. Beteiligte Einrichtung: ECRI, Plymouth Meeting, PA 19462, USA. Hauptthemen laut MEDLINE: Blood Glucose, Blood Glucose Self-Monitoring, Continuous Glucose Monitoring, Diabetes Mellitus, Type 2. Die Arbeit wurde bisher 80-mal zitiert (Crossref) und nennt 40 Literaturangaben.

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To provide a systematic review and meta-analysis synthesizing the findings of randomized controlled trials (RCTs) of continuous glucose monitors (CGMs) in the management of adults with type 2 diabetes mellitus (T2DM) on glucose control and clinical outcomes.

Methods

MEDLINE, Embase, and Cochrane were searched for RCTs that assessed the effectiveness of real-time CGM (rt-CGM) or flash CGM (FGM) in adults (≥18 years) with T2DM that reported on at least 1 of the following outcomes: hemoglobin A1c (HbA1c), time in range, time in hyperglycemia, or time in hypoglycemia. The GRADE approach was used to assess certainty of evidence for primary outcomes.

Results

Fourteen RCTs assessing CGM were included, with 825 patients in 9 RCTs using rt-CGM and 822 in 5 RCTs using FGM. Moderate certainty of evidence indicated that use of CGM had a modest but statistically significant reduction in HbA1c levels of about 0.32%. Our analyses of each device type separately showed similar reductions in HbA1c (0.34% and 0.33%, respectively, for rt-CGM and FGM), with trends for improvement in other glucose metrics favoring rt-CGM over self-monitored blood glucose.

Conclusion

Both rt-CGM and flash CGM led to modest but statistically significant declines in HbA1c among individuals with T2DM, with little heterogeneity in the results. However, the duration of the included RCTs was relatively short and few studies reported on important clinical outcomes, such as adverse events, emergency department use, or hospitalization. Longer term studies are needed to determine if the short-term improvements in glucose control leads to improvements in clinically important outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood GlucoseBlood Glucose Self-MonitoringContinuous Glucose MonitoringDiabetes Mellitus, Type 2Glycemic ControlRandomized Controlled Trials as TopicHumansGlycated HemoglobinHypoglycemiaHypoglycemic AgentsTreatment Outcome

Stichwörter der Autor:innen

continuous glucose monitorflash glucose monitoringglycemic controlmeta-analysissystematic reviewtype 2 diabetes mellitus

Substanzen

Blood GlucoseGlycated Hemoglobinhemoglobin A1c protein, humanHypoglycemic Agents

Autor:innen und Institutionen

  • ECRI, Plymouth Meeting, PA 19462, USA.
  • University of Arizona College of Medicine, Tucson, AZ 85724, USA.
  • Phoenix VA Healthcare System, Phoenix, AZ 85012, USA.

ORCID-Profile: Stacey Uhl

Zitieren

APA

Uhl, S., Choure, A., Rouse, B., Loblack, A., & Reaven, P. (2024). Effectiveness of Continuous Glucose Monitoring on Metrics of Glycemic Control in Type 2 Diabetes Mellitus: A Systematic Review and Meta-analysis of Randomized Controlled Trials. The Journal of Clinical Endocrinology & Metabolism, 109(4), 1119-1131. https://doi.org/10.1210/clinem/dgad652

Vancouver

Uhl S, Choure A, Rouse B, Loblack A, Reaven P. Effectiveness of Continuous Glucose Monitoring on Metrics of Glycemic Control in Type 2 Diabetes Mellitus: A Systematic Review and Meta-analysis of Randomized Controlled Trials. The Journal of Clinical Endocrinology & Metabolism. 2024;109(4):1119-1131. doi:10.1210/clinem/dgad652

BibTeX
@article{Uhl2024,
  author = {Uhl, Stacey and Choure, Anuja and Rouse, Benjamin and Loblack, Aggee and Reaven, Peter},
  title = {Effectiveness of Continuous Glucose Monitoring on Metrics of Glycemic Control in Type 2 Diabetes Mellitus: A Systematic Review and Meta-analysis of Randomized Controlled Trials},
  journal = {The Journal of Clinical Endocrinology & Metabolism},
  year = {2024},
  volume = {109},
  number = {4},
  pages = {1119--1131},
  doi = {10.1210/clinem/dgad652}
}
Kostenlos starten →