Quantitative modeling of lenticulostriate arteries on 7-T TOF-MRA for cerebral small vessel disease
European Radiology Experimental · 2024
DOI: 10.1186/s41747-024-00512-7 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift European Radiology Experimental, 2024. Verfasst von Zhixin Li und 11 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Brain and Cognitive Science, Institute of Biophysics, Chinese Academy of Sciences, 100101, Beijing, China. Hauptthemen laut MEDLINE: Magnetic Resonance Angiography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Ministry of Science and Technology of the People's Republic of China, Youth Innovation Promotion Association of the Chinese Academy of Sciences.
Abstract (Originalsprache)
Background
We developed a framework for segmenting and modeling lenticulostriate arteries (LSAs) on 7-T time-of-flight magnetic resonance angiography and tested its performance on cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL) patients and controls.
Methods
We prospectively included 29 CADASIL patients and 21 controls. The framework includes a small-patch convolutional neural network (SP-CNN) for fine segmentation, a random forest for modeling LSAs, and a screening model for removing wrong branches. The segmentation performance of our SP-CNN was compared to competitive networks. External validation with different resolution was performed on ten patients with aneurysms. Dice similarity coefficient (DSC) and Hausdorff distance (HD) between each network and manual segmentation were calculated. The modeling results of the centerlines, diameters, and lengths of LSAs were compared against manual labeling by four neurologists.
Results
The SP-CNN achieved higher DSC (92.741 ± 2.789, mean ± standard deviation) and lower HD (0.610 ± 0.141 mm) in the segmentation of LSAs. It also outperformed competitive networks in the external validation (DSC 82.6 ± 5.5, HD 0.829 ± 0.143 mm). The framework versus manual difference was lower than the manual inter-observer difference for the vessel length of primary branches (median -0.040 mm, interquartile range -0.209 to 0.059 mm) and secondary branches (0.202 mm, 0.016–0.537 mm), as well as for the offset of centerlines of primary branches (0.071 mm, 0.065–0.078 mm) and secondary branches (0.072, 0.064–0.080 mm), with p < 0.001 for all comparisons.
Conclusion
Our framework for LSAs modeling/quantification demonstrated high reliability and accuracy when compared to manual labeling.
Trial registration
NCT05902039 ( https://clinicaltrials.gov/study/NCT05902039?cond=NCT05902039 ). Relevance statement The proposed automatic segmentation and modeling framework offers precise quantification of the morphological parameters of lenticulostriate arteries. This innovative technology streamlines diagnosis and research of cerebral small vessel disease, eliminating the burden of manual labeling, facilitating cohort studies and clinical diagnosis. Key Points The morphology of LSAs is important in the diagnosis of CSVD but difficult to quantify. The proposed algorithm achieved the performance equivalent to manual labeling by neurologists. Our method can provide standardized quantitative results, reducing radiologists’ workload in cohort studies. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- State Key Laboratory of Brain and Cognitive Science, Institute of Biophysics, Chinese Academy of Sciences, 100101, Beijing, China.
- Anhui Province Key Laboratory of Biomedical Imaging and Intelligent Processing, Institute of Artificial Intelligence, Hefei Comprehensive National Science Center, 230088, Hefei, China.
- University of Chinese Academy of Sciences, 100049, Beijing, China.
- Department of Neurology, Peking University First Hospital, Beijing, China.
- Beijing Key Laboratory of Neurovascular Disease Discovery, Beijing, China.
- Beijing Institute of Brain Disorders, Capital Medical University, Beijing, China.
Förderung
- National Natural Science Foundation of China
- Ministry of Science and Technology of the People's Republic of China
- Youth Innovation Promotion Association of the Chinese Academy of Sciences
- Strategic Priority Research Program of the Chinese Academy of Sciences
Zitieren
APA
Li, Z., Sun, D., Ling, C., Bai, L., Zhang, J., Wu, Y., Yuan, Y., Wang, Z., Wang, Z., Zhuo, Y., Xue, R., & Zhang, Z. (2024). Quantitative modeling of lenticulostriate arteries on 7-T TOF-MRA for cerebral small vessel disease. European Radiology Experimental. https://doi.org/10.1186/s41747-024-00512-7
Vancouver
Li Z, Sun D, Ling C, Bai L, Zhang J, Wu Y, et al. Quantitative modeling of lenticulostriate arteries on 7-T TOF-MRA for cerebral small vessel disease. European Radiology Experimental. 2024. doi:10.1186/s41747-024-00512-7
BibTeX
@article{Li2024,
author = {Li, Zhixin and Sun, Dongbiao and Ling, Chen and Bai, Li and Zhang, Jinyuan and Wu, Yue and Yuan, Yun and Wang, Zhaoxia and Wang, Zhe and Zhuo, Yan and Xue, Rong and Zhang, Zihao},
title = {Quantitative modeling of lenticulostriate arteries on 7-T TOF-MRA for cerebral small vessel disease},
journal = {European Radiology Experimental},
year = {2024},
doi = {10.1186/s41747-024-00512-7}
}
EUVIMED