Effects of ankle–foot orthoses on gait parameters in post-stroke patients with different Brunnstrom stages of the lower limb: a single-center crossover trial
European Journal of Medical Research · 2024
DOI: 10.1186/s40001-024-01835-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Medical Research, 2024. Verfasst von Fangchao Wu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation Medicine, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, No. 3, Qingchun East Road, Shangcheng Distr…. Hauptthemen laut MEDLINE: Foot Orthoses, Stroke Rehabilitation, Gait Disorders, Neurologic, Stroke. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: This study was funded by the Zhejiang Medical Science and Technology Project.
Themen: Schlaganfall
Abstract (Originalsprache)
Background
Ankle-foot orthoses (AFO) can improve gait posture and walking ability in post-stroke patients. However, the effect of AFO on gait parameters in post-stroke patients according to the Brunnstrom stage of stroke recovery of the lower limbs remains unclear. The study aimed to investigate whether stroke patients with different Brunnstrom stages benefit from wearing AFO.
Methods
Twenty-five post-stroke participants included 18 men (50 ± 13 years) and 7 women (60 ± 15 years). The patients were divided based on Brunnstrom stage III or IV of the lower limbs. All patients underwent the gait and timed up and go (TUG) test using a gait analysis system while walking barefoot or with an AFO. The spatiotemporal and asymmetric parameters were analyzed.
Results
All 25 patients completed the study. Significant differences were observed between barefoot and AFO use in TUG time ( P < 0.001) but not walking velocity ( P > 0.05). The main effect of the swing time ratio was significant in both groups ( P < 0.05); however, the main effects of stride length, stance time, and gait asymmetry ratio were nonsignificant ( P > 0.05). For barefoot versus AFO, the main effects of stride length ( P < 0.05) and swing time ( P < 0.01) ratios were significant, whereas those of stance time and gait asymmetry ratio were nonsignificant ( P > 0.05).
Conclusions
Post-stroke patients with lower Brunnstrom stages benefitted more from AFO, particularly in gait asymmetry.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Rehabilitation Medicine, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, No. 3, Qingchun East Road, Shangcheng District, Hangzhou, People's Republic of China.
- Department of Rehabilitation Medicine, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, No. 3, Qingchun East Road, Shangcheng District, Hangzhou, People's Republic of China. jianhua_li@zju.edu.cn.
Förderung
- This study was funded by the Zhejiang Medical Science and Technology Project
Zitieren
APA
Wu, F., Meng, Z., Yang, K., & Li, J. (2024). Effects of ankle–foot orthoses on gait parameters in post-stroke patients with different Brunnstrom stages of the lower limb: a single-center crossover trial. European Journal of Medical Research. https://doi.org/10.1186/s40001-024-01835-2
Vancouver
Wu F, Meng Z, Yang K, Li J. Effects of ankle–foot orthoses on gait parameters in post-stroke patients with different Brunnstrom stages of the lower limb: a single-center crossover trial. European Journal of Medical Research. 2024. doi:10.1186/s40001-024-01835-2
BibTeX
@article{Wu2024,
author = {Wu, Fangchao and Meng, Zhe and Yang, Kezhen and Li, Jianhua},
title = {Effects of ankle–foot orthoses on gait parameters in post-stroke patients with different Brunnstrom stages of the lower limb: a single-center crossover trial},
journal = {European Journal of Medical Research},
year = {2024},
doi = {10.1186/s40001-024-01835-2}
}
EUVIMED