EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Soft X-ray tomography analysis of mitochondria dynamics in Saccharomyces cerevisiae

Wei-Ling Huang, Chang-Lin Chen, Zi-Jing Lin, Chia-Chun Hsieh, Mo Da-Sang Hua, Chih-Chan Cheng, Tzu-Hao Cheng, Lee-Jene Lai, Chuang-Rung Chang

Biology Direct · 2024

DOI: 10.1186/s13062-024-00570-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biology Direct, 2024. Verfasst von Wei-Ling Huang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Biotechnology, National Tsing Hua University, Hsinchu, Taiwan. Hauptthemen laut MEDLINE: Saccharomyces cerevisiae, Mitochondrial Dynamics, Mitochondria, Tomography, X-Ray. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science and Technology Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Mitochondria are highly dynamic organelles that constantly undergo processes of fission and fusion. The changes in mitochondrial dynamics shape the organellar morphology and influence cellular activity regulation. Soft X-ray tomography (SXT) allows for three-dimensional imaging of cellular structures while they remain in their natural, hydrated state, which omits the need for cell fixation and sectioning. Synchrotron facilities globally primarily use flat grids as sample carriers for SXT analysis, focusing on adherent cells. To investigate mitochondrial morphology and structure in hydrated yeast cells using SXT, it is necessary to establish a method that employs the flat grid system for examining cells in suspension.

Results

We developed a procedure to adhere suspended yeast cells to a flat grid for SXT analysis. Using this protocol, we obtained images of wild-type yeast cells, strains with mitochondrial dynamics defects, and mutant cells possessing distinctive mitochondria. The SXT images align well with the results from fluorescent microscopy. Optimized organellar visualization was achieved by constructing three-dimensional models of entire yeast cells.

Conclusions

In this study, we characterized the mitochondrial network in yeast cells using SXT. The optimized sample preparation procedure was effective for suspended cells like yeast, utilizing a flat grid system to analyze mitochondrial structure through SXT. The findings corresponded with the mitochondrial morphology observed under fluorescence microscopy, both in regular and disrupted dynamic equilibrium. With the acquired image of unique mitochondria in Δhap2 cells, our results revealed that intricate details of organelles, such as mitochondria and vacuoles in yeast cells, can be characterized using SXT. Therefore, this optimized system supports the expanded application of SXT for studying organellar structure and morphology in suspended cells.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Saccharomyces cerevisiaeMitochondrial DynamicsMitochondriaTomography, X-RayImaging, Three-Dimensional

Stichwörter der Autor:innen

MitochondriaSoft X-ray tomographyYeast

Autor:innen und Institutionen

  • Institute of Biotechnology, National Tsing Hua University, Hsinchu, Taiwan.
  • Experimental Facility Division, National Synchrotron Radiation Research Center, Hsinchu, Taiwan.
  • Institute of Biochemistry and Molecular Biology, National Yang Ming Chiao Tung University, Taipei, Taiwan.
  • Experimental Facility Division, National Synchrotron Radiation Research Center, Hsinchu, Taiwan. jene@nsrrc.org.tw.
  • Institute of Biotechnology, National Tsing Hua University, Hsinchu, Taiwan. crchang@life.nthu.edu.tw.

Förderung

  • National Science and Technology Council

Zitieren

APA

Huang, W. L., Chen, C. L., Lin, Z. J., Hsieh, C. C., Hua, M. D., Cheng, C. C., Cheng, T. H., Lai, L. J., & Chang, C. R. (2024). Soft X-ray tomography analysis of mitochondria dynamics in Saccharomyces cerevisiae. Biology Direct. https://doi.org/10.1186/s13062-024-00570-2

Vancouver

Huang WL, Chen CL, Lin ZJ, Hsieh CC, Hua MD, Cheng CC, et al. Soft X-ray tomography analysis of mitochondria dynamics in Saccharomyces cerevisiae. Biology Direct. 2024. doi:10.1186/s13062-024-00570-2

BibTeX
@article{Huang2024,
  author = {Huang, Wei-Ling and Chen, Chang-Lin and Lin, Zi-Jing and Hsieh, Chia-Chun and Hua, Mo Da-Sang and Cheng, Chih-Chan and Cheng, Tzu-Hao and Lai, Lee-Jene and Chang, Chuang-Rung},
  title = {Soft X-ray tomography analysis of mitochondria dynamics in Saccharomyces cerevisiae},
  journal = {Biology Direct},
  year = {2024},
  doi = {10.1186/s13062-024-00570-2}
}
Kostenlos starten →