EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Compliance of volunteers in a fully-enclosed patient rotation system for MR-guided radiation therapy: a prospective study

Cedric Beyer, Katharina Maria Paul, Stefan Dorsch, Gernot Echner, Fabian Dinkel, Thomas Welzel, Katharina Seidensaal, Juliane Hörner-Rieber, Oliver Jäkel, Jürgen Debus, Sebastian Klüter

Radiation Oncology · 2024

DOI: 10.1186/s13014-024-02461-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Oncology, 2024. Verfasst von Cedric Beyer und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany. cedric.beyer@med.uni-heidelber…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Radiotherapy, Image-Guided. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bundesministerium für Bildung und Forschung, Deutsche Forschungsgemeinschaft, Universitätsklinikum Heidelberg.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Particle therapy makes a noteworthy contribution in the treatment of tumor diseases. In order to be able to irradiate from different angles, usually expensive, complex and large gantries are used. Instead rotating the beam via a gantry, the patient itself might be rotated. Here we present tolerance and compliance of volunteers for a fully-enclosed patient rotation system in a clinical magnetic resonance (MR)-scanner for potential use in MR-guided radiotherapy, conducted within a prospective evaluation study.

Methods

A patient rotation system was used to simulate and perform magnetic resonance imaging (MRI)-examinations with 50 volunteers without an oncological question. For 20 participants, the MR-examination within the bore was simulated by introducing realistic MRI noise, whereas 30 participants received an examination with image acquisition. Initially, body parameters and claustrophobia were assessed. The subjects were then rotated to different angles for simulation (0°, 45°, 90°, 180°) and imaging (0°, 70°, 90°, 110°). At each angle, anxiety and motion sickness were assessed using a 6-item State-Trait-Anxiety-Inventory (STAI-6) and a modified Motion Sickness Assessment Questionnaire (MSAQ). In addition, general areas of discomfort were evaluated.

Results

Out of 50 subjects, three (6%) subjects terminated the study prematurely. One subject dropped out during simulation due to nausea while rotating to 45°. During imaging, further two subjects dropped out due to shoulder pain from positioning at 90° and 110°, respectively. The average result for claustrophobia (0 = no claustrophobia to 4 = extreme claustrophobia) was none to light claustrophobia (average score: simulation 0.64 ± 0.33, imaging 0.51 ± 0.39). The mean anxiety scores (0% = no anxiety to 100% = maximal anxiety) were 11.04% (simulation) and 15.82% (imaging). Mean motion sickness scores (0% = no motion sickness to 100% = maximal motion sickness) of 3.5% (simulation) and 6.76% (imaging) were obtained across all participants.

Conclusion

Our study proves the feasibility of horizontal rotation in a fully-enclosed rotation system within an MR-scanner. Anxiety scores were low and motion sickness was only a minor influence. Both anxiety and motion sickness showed no angular dependency. Further optimizations with regard to immobilization in the rotation device may increase subject comfort.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingRadiotherapy, Image-GuidedHumansProspective StudiesMaleFemaleAdultRotationMiddle AgedYoung AdultMotion SicknessPatient ComplianceAnxietyHealthy Volunteers

Stichwörter der Autor:innen

MR-guided radiotherapyMRIParticle therapyPatient positioningPatient rotation

Autor:innen und Institutionen

  • Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany. cedric.beyer@med.uni-heidelberg.de.
  • Heidelberg Institute of Radiation Oncology (HIRO) and National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany. cedric.beyer@med.uni-heidelberg.de.
  • National Center for Tumor Diseases (NCT), Heidelberg, Germany. cedric.beyer@med.uni-heidelberg.de.
  • Department of Radiation Oncology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
  • Heidelberg Institute of Radiation Oncology (HIRO) and National Center for Radiation Research in Oncology (NCRO), Heidelberg, Germany.
  • National Center for Tumor Diseases (NCT), Heidelberg, Germany.

Förderung

  • Bundesministerium für Bildung und Forschung
  • Deutsche Forschungsgemeinschaft
  • Universitätsklinikum Heidelberg

Zitieren

APA

Beyer, C., Paul, K. M., Dorsch, S., Echner, G., Dinkel, F., Welzel, T., Seidensaal, K., Hörner-Rieber, J., Jäkel, O., Debus, J., & Klüter, S. (2024). Compliance of volunteers in a fully-enclosed patient rotation system for MR-guided radiation therapy: a prospective study. Radiation Oncology. https://doi.org/10.1186/s13014-024-02461-2

Vancouver

Beyer C, Paul KM, Dorsch S, Echner G, Dinkel F, Welzel T, et al. Compliance of volunteers in a fully-enclosed patient rotation system for MR-guided radiation therapy: a prospective study. Radiation Oncology. 2024. doi:10.1186/s13014-024-02461-2

BibTeX
@article{Beyer2024,
  author = {Beyer, Cedric and Paul, Katharina Maria and Dorsch, Stefan and Echner, Gernot and Dinkel, Fabian and Welzel, Thomas and Seidensaal, Katharina and Hörner-Rieber, Juliane and Jäkel, Oliver and Debus, Jürgen and Klüter, Sebastian},
  title = {Compliance of volunteers in a fully-enclosed patient rotation system for MR-guided radiation therapy: a prospective study},
  journal = {Radiation Oncology},
  year = {2024},
  doi = {10.1186/s13014-024-02461-2}
}
Kostenlos starten →