EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

A hybrid CNN-Bi-LSTM model with feature fusion for accurate epilepsy seizure detection

Xiaoshuai Cao, Shaojie Zheng, Jincan Zhang, Wenna Chen, Ganqin Du

BMC Medical Informatics and Decision Making · 06.01.2025 · 25 (1)

DOI: 10.1186/s12911-024-02845-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift BMC Medical Informatics and Decision Making, online erschienen am 06.01.2025. Verfasst von Xiaoshuai Cao und 4 weiteren Autor:innen. Beteiligte Einrichtung: The First Affiliated Hospital, and College of Clinical Medicine of Henan University of Science and Technology, Luoyang, China. Hauptthemen laut MEDLINE: Epilepsy, Electroencephalography, Seizures, Neural Networks, Computer. Die Arbeit wurde bisher 106-mal zitiert (Crossref) und nennt 66 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Foundation of Henan Educational Committee, Major Science and Technology Projects of Henan Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The diagnosis and treatment of epilepsy continue to face numerous challenges, highlighting the urgent need for the development of rapid, accurate, and non-invasive methods for seizure detection. In recent years, advancements in the analysis of electroencephalogram (EEG) signals have garnered widespread attention, particularly in the area of seizure recognition. METHODS: A novel hybrid deep learning approach that combines feature fusion for efficient seizure detection is proposed in this study. First, the Discrete Wavelet Transform (DWT) is applied to perform a five-level decomposition of the raw EEG signals, from which time-frequency and nonlinear features are extracted from the decomposed sub-bands. To eliminate redundant features, Support Vector Machine-Recursive Feature Elimination (SVM-RFE) is employed to select the most distinctive features for fusion. Finally, seizure states are classified using Convolutional Neural Network-Bidirectional Long Short-Term Memory (CNN-Bi-LSTM). RESULTS: The method was rigorously validated on the Bonn and New Delhi datasets. In the binary classification tasks, both the D-E group (Bonn dataset) and the Interictal-Ictal group (New Delhi dataset) achieved 100% accuracy, 100% sensitivity, 100% specificity, 100% precision, and 100% F1-score. In the three-class classification task A-D-E on the Bonn dataset, the model performed excellently, achieving 96.19% accuracy, 95.08% sensitivity, 97.34% specificity, 97.49% precision, and 96.18% F1-score. In addition, the proposed method was further validated on the larger and more clinically relevant CHB-MIT dataset, achieving average metrics of 98.43% accuracy, 97.84% sensitivity, 99.21% specificity, 99.14% precision, and an F1 score of 98.39%. Compared to existing literature, our method outperformed several recent studies in similar classification tasks, underscoring the effectiveness and advancement of the approach presented in this research. CONCLUSION: The findings indicate that the proposed method demonstrates a high level of effectiveness in detecting seizures, which is a crucial aspect of managing epilepsy. By improving the accuracy of seizure detection, this method has the potential to significantly enhance the process of diagnosing and treating individuals affected by epilepsy. This advancement could lead to more tailored treatment plans, timely interventions, and ultimately, better quality of life for patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

EpilepsyElectroencephalographySeizuresNeural Networks, ComputerHumansDeep LearningSupport Vector MachineWavelet Analysis

Stichwörter der Autor:innen

Bidirectional Long Short-Term MemoryConvolutional Neural NetworkElectroencephalography (EEG)Feature FusionSeizure Detection

Autor:innen und Institutionen

  • The First Affiliated Hospital, and College of Clinical Medicine of Henan University of Science and Technology, Luoyang, China.
  • College of Information Engineering, Henan University of Science and Technology, Luoyang, China.
  • The First Affiliated Hospital, and College of Clinical Medicine of Henan University of Science and Technology, Luoyang, China. chenwenna0408@163.com.
  • The First Affiliated Hospital, and College of Clinical Medicine of Henan University of Science and Technology, Luoyang, China. dgq99@163.com.

Förderung

  • Foundation of Henan Educational Committee
  • Major Science and Technology Projects of Henan Province

Zitieren

APA

Cao, X., Zheng, S., Zhang, J., Chen, W., & Du, G. (2025). A hybrid CNN-Bi-LSTM model with feature fusion for accurate epilepsy seizure detection. BMC Medical Informatics and Decision Making, 25(1). https://doi.org/10.1186/s12911-024-02845-0

Vancouver

Cao X, Zheng S, Zhang J, Chen W, Du G. A hybrid CNN-Bi-LSTM model with feature fusion for accurate epilepsy seizure detection. BMC Medical Informatics and Decision Making. 2025;25(1). doi:10.1186/s12911-024-02845-0

BibTeX
@article{Cao2025,
  author = {Cao, Xiaoshuai and Zheng, Shaojie and Zhang, Jincan and Chen, Wenna and Du, Ganqin},
  title = {A hybrid CNN-Bi-LSTM model with feature fusion for accurate epilepsy seizure detection},
  journal = {BMC Medical Informatics and Decision Making},
  year = {2025},
  volume = {25},
  number = {1},
  doi = {10.1186/s12911-024-02845-0}
}
Kostenlos starten →