Comparison of NeedleTrainer™ and ultrasound tissue simulator in a simulated environment among novice regional anaesthesia practitioners

Mohammad Nizam Mokhtar, Siti Aisyah Suhaini, Weng Ken Chan, Iskandar Khalid, Kok Wang Tan, Angelina Chia Chia Lim, Maryam Budiman, Afifah Samsudin, Asmah Azizeh, Vimal Varma Spor Madiman, Azarinah Izaham

BMC Medical Education · 2024

DOI: 10.1186/s12909-024-06361-7 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift BMC Medical Education, 2024. Verfasst von Mohammad Nizam Mokhtar und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anaesthesiology & Intensive Care, Faculty of Medicine, Universiti Kebangsaan Malaysia, Jalan Yaacob Latif, 56000, Bandar Tun Razak, Kua…. Hauptthemen laut MEDLINE: Simulation Training, Clinical Competence, Anesthesia, Conduction. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Utilising ultrasound technology has resulted in higher success and lower complication rates during regional anaesthesia (RA) procedures. Proper training is necessary to accurately identify structures, optimise images, and improve hand-eye coordination. Simulation training using immersive virtual environments and simulation models has enabled this competency training to be conducted safely before performing on patients. We conducted a study to compare the simulator performance and users' feedback on a Blue Phantom Regional Anaesthesia Ultrasound Training Block and NeedleTrainer™. METHODS: Forty-seven participants were recruited via convenient sampling during a RA workshop for novice practitioners. They were divided into the N or B group and then crossover to experience using both Blue Phantom and NeedleTrainer model. Time-to-reach-target, first-pass success rate, and complication rate were assessed, while the learning and confidence scores were rated using six-item and three-item questionnaires, respectively, via a 5-point Likert scale. RESULTS: Blue Phantom model has a longer time-to-target as compared to the NeedleTrainer model (16 ± 8 vs 8 ± 3 s, p < 0.001), higher first- pass success rate (100% vs 80.9%), and lower complication rate (0% vs 19.1%). Higher overall learning satisfaction scores (28 ± 4 vs 25 ± 4, p = 0.003) and confidence scores after training (13 ± 2 vs 12 ± 2, p < 0.001) were recorded for the Blue Phantom model. CONCLUSIONS: We postulated that the artificial intelligence structure recognition software enables NeedleTrainer users to attain shorter time-to-target. That being said, Blue Phantom provides better operator learning satisfaction, improved confidence, higher success and lower complication rates among novice RA practitioners, possibly due to greater tactile feedback during the simulated training.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Simulation TrainingClinical CompetenceAnesthesia, ConductionHumansMaleAdultFemalePhantoms, ImagingCross-Over StudiesAnesthesiologyUltrasonography, Interventional

Stichwörter der Autor:innen

Blue phantomNeedleTrainerRegional anaesthesiaUltrasound simulator

Autor:innen und Institutionen

  • Department of Anaesthesiology & Intensive Care, Faculty of Medicine, Universiti Kebangsaan Malaysia, Jalan Yaacob Latif, 56000, Bandar Tun Razak, Kuala Lumpur, Malaysia. drnizam@ukm.edu.my.
  • Department of Anaesthesiology & Intensive Care, Faculty of Medicine, Universiti Kebangsaan Malaysia, Jalan Yaacob Latif, 56000, Bandar Tun Razak, Kuala Lumpur, Malaysia.
  • Department of Anaesthesiology & Intensive Care, Faculty of Medicine, Universiti Teknologi MARA, Jalan Hospital, Sungai Buloh, 47000, Selangor, Malaysia.

Zitieren

APA

Mokhtar, M. N., Suhaini, S. A., Chan, W. K., Khalid, I., Tan, K. W., Lim, A. C. C., Budiman, M., Samsudin, A., Azizeh, A., Spor Madiman, V. V., & Izaham, A. (2024). Comparison of NeedleTrainer™ and ultrasound tissue simulator in a simulated environment among novice regional anaesthesia practitioners. BMC Medical Education. https://doi.org/10.1186/s12909-024-06361-7

Vancouver

Mokhtar MN, Suhaini SA, Chan WK, Khalid I, Tan KW, Lim ACC, et al. Comparison of NeedleTrainer™ and ultrasound tissue simulator in a simulated environment among novice regional anaesthesia practitioners. BMC Medical Education. 2024. doi:10.1186/s12909-024-06361-7

BibTeX
@article{Mokhtar2024,
  author = {Mokhtar, Mohammad Nizam and Suhaini, Siti Aisyah and Chan, Weng Ken and Khalid, Iskandar and Tan, Kok Wang and Lim, Angelina Chia Chia and Budiman, Maryam and Samsudin, Afifah and Azizeh, Asmah and Spor Madiman, Vimal Varma and Izaham, Azarinah},
  title = {Comparison of NeedleTrainer™ and ultrasound tissue simulator in a simulated environment among novice regional anaesthesia practitioners},
  journal = {BMC Medical Education},
  year = {2024},
  doi = {10.1186/s12909-024-06361-7}
}
Kostenlos starten →