The suture fixation of the levonorgestrel-releasing intrauterine device with hysteroscope for the treatment of adenomyosis in patients at high risk of device expulsion-a prospective observational study
BMC Women's Health · 09.10.2024 · 24 (1)
DOI: 10.1186/s12905-024-03390-8 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift BMC Women's Health, online erschienen am 09.10.2024. Verfasst von Min Mao und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gynecology, Chengdu First People's Hospital, Sichuan Province, Chengdu, 610000, China. Hauptthemen laut MEDLINE: Adenomyosis, Levonorgestrel, Intrauterine Devices, Medicated, Hysteroscopy. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
BACKGROUND: This study aimed to investigate the safety and efficacy of suture fixation of the levonorgestrel-releasing intrauterine device (LNG-IUD) by hysteroscope for the treatment of adenomyosis in patients at high risk of device expulsion, to provide a viable treatment option for these patients. METHODS: Twenty-one patients with large symptomatic adenomyosis were sewed and fixed with the LNG-IUD in the uterus by hysteroscopy to prevent the device expulsion. RESULTS: In this prospective case series, all 21 patients were successfully sewed and fixed with the LNG-IUD in the uterus by hysteroscopy. The amount of menstruation was significantly decreased and dysmenorrhea was significantly relieved in 3, 6, and 12 months after surgery compared with before surgery. Only one patient underwent a laparoscopic hysterectomy due to dysmenorrhea which was not alleviated one month later. Serious IUD complications including expulsion and perforation were not observed. There was no development of new side effects than LNG-IUD insertion. CONCLUSION: Our findings indicate that suture fixation of the LNG-IUD by hysteroscope is a safe, effective, and minimally invasive surgical procedure to prevent the device expulsion. It is a good solution for the treatment of large symptomatic adenomyosis and has shown to be effective in managing symptoms related to adenomyosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Gynecology, Chengdu First People's Hospital, Sichuan Province, Chengdu, 610000, China.
- Surgical center, Chengdu First People's Hospital, Chengdu, Sichuan Province, China.
- Department of Gynecology, Chengdu First People's Hospital, Sichuan Province, Chengdu, 610000, China. 741576339@qq.com.
- West China Second University Hospital, Sichuan University, Key Laboratory of Birth Defects and Related Diseases of Women and Children Sichuan University, Ministry of Education, Chengdu, Sichuan Province, China. zisu_yu@…
Zitieren
APA
Mao, M., Gou, Y., Luo, Z., Li, Y., & Tong, Y. (2024). The suture fixation of the levonorgestrel-releasing intrauterine device with hysteroscope for the treatment of adenomyosis in patients at high risk of device expulsion-a prospective observational study. BMC Women's Health, 24(1). https://doi.org/10.1186/s12905-024-03390-8
Vancouver
Mao M, Gou Y, Luo Z, Li Y, Tong Y. The suture fixation of the levonorgestrel-releasing intrauterine device with hysteroscope for the treatment of adenomyosis in patients at high risk of device expulsion-a prospective observational study. BMC Women's Health. 2024;24(1). doi:10.1186/s12905-024-03390-8
BibTeX
@article{Mao2024,
author = {Mao, Min and Gou, Yuanqin and Luo, Zhigui and Li, Yuanhong and Tong, Yu},
title = {The suture fixation of the levonorgestrel-releasing intrauterine device with hysteroscope for the treatment of adenomyosis in patients at high risk of device expulsion-a prospective observational study},
journal = {BMC Women's Health},
year = {2024},
volume = {24},
number = {1},
doi = {10.1186/s12905-024-03390-8}
}