Thickness-dependent biomechanical accuracy of additively manufactured and thermoformed orthodontic aligners: an in vitro comparative study
BMC Oral Health · 29.05.2026 · 26 (1)
DOI: 10.1186/s12903-026-08758-w ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift BMC Oral Health, online erschienen am 29.05.2026. Verfasst von Ovilya Hassan Omer und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, College of Dentistry, University of Sulaimani, Sulaymaniyah, 46001, Iraq. Hauptthemen laut MEDLINE: Orthodontic Appliance Design, Tooth Movement Techniques, Printing, Three-Dimensional. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
BACKGROUND: Additive manufacturing has introduced directly printed orthodontic aligners as an alternative to thermoforming. However, comparative data regarding thickness-dependent biomechanical accuracy remain limited. Therefore, this study aimed to evaluate the influence of fabrication method (thermoforming vs. direct 3D printing) and material thickness (0.76 mm vs. 1.0 mm) on the accuracy of rotational, tipping, and torque movements of different teeth under standardized in vitro conditions. METHODS: Thirty-six standardized typodonts underwent digital staging (30° rotation, 10° mesial tipping, 10° positive torque). Aligners were fabricated via thermoforming (Zendura A) or direct 3D printing (Tera Harz TC-85). Movement was simulated using thermal activation (56 °C, 90 s). Pre- and post-movement scans were superimposed (Geomagic Control X), and accuracy was calculated as the percentage of achieved to programmed movement. Analyses were performed at both typodont and tooth levels. Statistical analysis was conducted using Jamovi (version 2.6.44), applying two-way ANOVA and Mann-Whitney U tests (p < 0.05). RESULTS: Aligner thickness significantly improved accuracy across all movement types (p < 0.001). In contrast, fabrication method showed inconsistent effects, with only isolated significant differences. Mesial tipping demonstrated the highest predictability (up to 92.67%), whereas torque showed the lowest (maximum 71.67%). Accuracy was generally higher in anterior teeth, with greater variability in posterior segments. No significant arch differences were observed. CONCLUSIONS: Aligner thickness is the primary determinant of biomechanical accuracy, with thicker aligners providing more predictable tooth movement. Fabrication method showed a secondary and variable influence, indicating that material thickness plays a more critical role in optimizing aligner biomechanics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthodontics, College of Dentistry, University of Sulaimani, Sulaymaniyah, 46001, Iraq.
- Department of Digital Dentistry, College of Dentistry, University of Sulaimani, City Campus, Madam Mitterrand Street, Sulaimani, Sulaymaniyah, 46001, Iraq. zhwan.rasheed@univsul.edu.iq.
ORCID-Profile: Zhwan Jamal Rashid
Zitieren
APA
Omer, O. H., & Rashid, Z. J. (2026). Thickness-dependent biomechanical accuracy of additively manufactured and thermoformed orthodontic aligners: an in vitro comparative study. BMC Oral Health, 26(1). https://doi.org/10.1186/s12903-026-08758-w
Vancouver
Omer OH, Rashid ZJ. Thickness-dependent biomechanical accuracy of additively manufactured and thermoformed orthodontic aligners: an in vitro comparative study. BMC Oral Health. 2026;26(1). doi:10.1186/s12903-026-08758-w
BibTeX
@article{Omer2026,
author = {Omer, Ovilya Hassan and Rashid, Zhwan Jamal},
title = {Thickness-dependent biomechanical accuracy of additively manufactured and thermoformed orthodontic aligners: an in vitro comparative study},
journal = {BMC Oral Health},
year = {2026},
volume = {26},
number = {1},
doi = {10.1186/s12903-026-08758-w}
}
EUVIMED