Mechanical analysis of 3D printed dental restorations manufactured using different resins and validation with FEM analysis
BMC Oral Health · 2025
DOI: 10.1186/s12903-024-05384-2 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift BMC Oral Health, 2025. Verfasst von Buse Cebi Gul und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Faculty of Dentistry of Inonu University, Malatya, 44280, Turkey. buse.cebi@hotmail.com. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Composite Resins, Crowns, Dental Prosthesis Design. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
PURPOSE: The aim of this study was to compare the wear and fracture resistance of single crowns produced from newly developed 3D printer resins used to produce permanent crowns and currently used composite CAD/CAM discs, after being thermomechanically aged in a chewing simulator. MATERIALS AND METHODS: A total of 112 stainless steel die models simulating mandibular left first molars were produced, 8 for each group. Single crowns were produced from 3 different discs (Grandio Voco [GR], breCAM HIPC [HC], and Shofu HC [SF]) by CAD/CAM milling method and manufactured from from 4 different permanent composite resins (Nexdent C&B MFH [ND], Permanent Bridge Saremco [PB], VarseoSmile Crownplus [VSC], and Şenertek P-Crown [PC]) using the 3D printing method. Stereomicroscopy, scanning electron microscope (SEM) and Finite Element Method (FEM) analysis was performed. Data were analyzed using ANOVA, paired-t tests and Tukey's HSD test (alpha = 0.05). RESULTS: As a result of thermomechanical aging, significant difference was found between the groups in wear and fracture resistance (P < .05). The highest wear resistance was found in the VSC group, and the lowest wear resistance in the PC group. As a result of the compression test, the highest fracture resistance was noted in the GR group and the lowest in the PC group. FEM analysis performed to validate fracture experiments showed an 87% similarity to the in-vitro data. CONCLUSIONS: The crowns in all groups produced by CAD/CAM milling and 3D printing provided acceptable in vitro wear and fracture resistance for clinical application. The wear and fracture resistance of resin-based materials should be supported by clinical studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics, Faculty of Dentistry of Inonu University, Malatya, 44280, Turkey. buse.cebi@hotmail.com.
- Department of Prosthodontics, Faculty of Dentistry of Inonu University, Malatya, 44280, Turkey.
- Department of Mechanical Engineer, Faculty of Engineering, of Inonu University, Malatya, Turkey.
- Clinic of Masticatory Disorders and Dental Biomaterials, Center for Dental Medicine, University of Zurich, Zurich, Switzerland.
Zitieren
APA
Gul, B. C., Demirci, F., Baki, N., Bahce, E., & Özcan, M. (2025). Mechanical analysis of 3D printed dental restorations manufactured using different resins and validation with FEM analysis. BMC Oral Health. https://doi.org/10.1186/s12903-024-05384-2
Vancouver
Gul BC, Demirci F, Baki N, Bahce E, Özcan M. Mechanical analysis of 3D printed dental restorations manufactured using different resins and validation with FEM analysis. BMC Oral Health. 2025. doi:10.1186/s12903-024-05384-2