Cone-beam CT landmark detection for measuring basal bone width: a retrospective validation study
BMC Oral Health · 2024
DOI: 10.1186/s12903-024-04798-2 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift BMC Oral Health, 2024. Verfasst von Juan Dai und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Stomatology, Shenzhen University General Hospital, Shenzhen University Clinical Medical Academy, Xueyuan Avenue, Nanshan District, Shen…. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Anatomic Landmarks, Maxilla. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: The Science Technology and Innovation Committee of Shenzhen, The National Natural Science Foundation of China.
Abstract (Originalsprache)
BACKGROUND: Accurate assessment of basal bone width is essential for distinguishing individuals with normal occlusion from patients with maxillary transverse deficiency who may require maxillary expansion. Herein, we evaluated the effectiveness of a deep learning (DL) model in measuring landmarks of basal bone width and assessed the consistency of automated measurements compared to manual measurements. METHODS: Based on the U-Net algorithm, a coarse-to-fine DL model was developed and trained using 80 cone-beam computed tomography (CBCT) images. The model's prediction capabilities were validated on 10 CBCT scans and tested on an additional 34. To evaluate the performance of the DL model, its measurements were compared with those taken manually by one junior orthodontist using the concordance correlation coefficient (CCC). RESULTS: It took approximately 1.5 s for the DL model to perform the measurement task in only CBCT images. This framework showed a mean radial error of 1.22 ± 1.93 mm and achieved successful detection rates of 71.34%, 81.37%, 86.77%, and 91.18% in the 2.0-, 2.5-, 3.0-, and 4.0-mm ranges, respectively. The CCCs (95% confidence interval) of the maxillary basal bone width and mandibular basal bone width distance between the DL model and manual measurement for the 34 cases were 0.96 (0.94-0.97) and 0.98 (0.97-0.99), respectively. CONCLUSION: The novel DL framework developed in this study improved the diagnostic accuracy of the individual assessment of maxillary width. These results emphasize the potential applicability of this framework as a computer-aided diagnostic tool in orthodontic practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Stomatology, Shenzhen University General Hospital, Shenzhen University Clinical Medical Academy, Xueyuan Avenue, Nanshan District, Shenzhen, Guangdong, 518055, China.
- Medical AI Lab, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen, 518060, China.
- Guangdong Key Laboratory of Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen, 518060, China.
- Medical AI Lab, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen, 518060, China. huangb@szu.edu.cn.
- Guangdong Key Laboratory of Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen, 518060, China. huangb@szu.edu.cn.
Förderung
- The Science Technology and Innovation Committee of Shenzhen
- The National Natural Science Foundation of China
Zitieren
APA
Dai, J., Guo, X., Zhang, H., Xie, H., Huang, J., Huang, Q., & Huang, B. (2024). Cone-beam CT landmark detection for measuring basal bone width: a retrospective validation study. BMC Oral Health. https://doi.org/10.1186/s12903-024-04798-2
Vancouver
Dai J, Guo X, Zhang H, Xie H, Huang J, Huang Q, et al. Cone-beam CT landmark detection for measuring basal bone width: a retrospective validation study. BMC Oral Health. 2024. doi:10.1186/s12903-024-04798-2
BibTeX
@article{Dai2024,
author = {Dai, Juan and Guo, Xinge and Zhang, Hongyuan and Xie, Haoyu and Huang, Jiahui and Huang, Qiangtai and Huang, Bingsheng},
title = {Cone-beam CT landmark detection for measuring basal bone width: a retrospective validation study},
journal = {BMC Oral Health},
year = {2024},
doi = {10.1186/s12903-024-04798-2}
}
EUVIMED