EUVIMEDEUVIMED entdecken
StudienprotokollOpen Access · CC BY 4.0

Safety and effectiveness of using Disposable Ultrasonic shears to coagulate 5–7 mm blood vessels: protocol for a prospective, multicenter, randomized, parallel controlled, non-inferiority clinical trial

Xipeng Wang, Chengqiang Li, Junqiang Fan, Jian Hu, Mingsong Wang, Hecheng Li

BMC Surgery · 19.07.2024 · 24 (1)

DOI: 10.1186/s12893-024-02497-x ↗

Kurz gefasst

Studienprotokoll in der Zeitschrift BMC Surgery, online erschienen am 19.07.2024. Verfasst von Xipeng Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Thoracic Surgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China. Hauptthemen laut MEDLINE: Disposable Equipment. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The ultrasonic scalpel is widely used during surgery. It is safe and effective to close the pulmonary artery branch vessels of 7 mm or below with an ultrasonic energy device as reported. However, there have been no multicenter randomized clinical trial to assess the safety and effectiveness of using ultrasonic scalpel to coagulate 5–7 mm blood vessels in thoracic surgery.

Methods

This is a prospective, multicenter, randomized, parallel controlled, non-inferiority clinical trial. A total of 144 eligible patients planning to undergo lung or esophageal surgery will be randomly allocated to the experimental group and the control group. The investigational product (Disposable Ultrasonic Shears manufactured by Reach Surgical, Inc.) and the control product (Harmonic Ace + 7, 5 mm Diameter Shears with Advanced Hemostasis) will be used in each group. The primary endpoint is the success rate of coagulating target blood vessels during surgery. Secondary endpoints include postoperative rebleeding, intraoperative bleeding volume, drainage volume, surgical duration, etc. Postoperative follow-up before and after discharge will be performed.

Discussion

This clinical trial aims to evaluate the safety and effectiveness of using the investigational product (Disposable Ultrasonic Shears manufactured by Reach Surgical, Inc.) and that of the control product (Harmonic Ace + 7, 5 mm Diameter Shears with Advanced Hemostasis) to coagulate 5–7 mm blood vessels in thoracic surgery.

Trial registration

ClinicalTrials.gov: NCT06002737. The trial was prospectively registered on 16 August 2023, https://www.clinicaltrials.gov/study/NCT06002737 .

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Disposable EquipmentAdultFemaleHumansMaleMiddle AgedBlood Loss, SurgicalEquivalence Trials as TopicEsophagusHemostasis, SurgicalMulticenter Studies as TopicProspective StudiesThoracic Surgical ProceduresTreatment OutcomeUltrasonic Surgical Procedures

Stichwörter der Autor:innen

5-7 mm blood vesselsDisposable Ultrasonic shearsSurgical instrumentsThoracic surgery

Autor:innen und Institutionen

  • Department of Thoracic Surgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Department of Thoracic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.
  • Department of Thoracic Surgery, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.
  • Key Laboratory of Clinical Evaluation Technology for Medical Device of Zhejiang Province, Hangzhou, China.
  • Department of Thoracic Surgery, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Department of Thoracic Surgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China. lihecheng2000@hotmail.com.

Zitieren

APA

Wang, X., Li, C., Fan, J., Hu, J., Wang, M., & Li, H. (2024). Safety and effectiveness of using Disposable Ultrasonic shears to coagulate 5–7 mm blood vessels: protocol for a prospective, multicenter, randomized, parallel controlled, non-inferiority clinical trial. BMC Surgery, 24(1). https://doi.org/10.1186/s12893-024-02497-x

Vancouver

Wang X, Li C, Fan J, Hu J, Wang M, Li H. Safety and effectiveness of using Disposable Ultrasonic shears to coagulate 5–7 mm blood vessels: protocol for a prospective, multicenter, randomized, parallel controlled, non-inferiority clinical trial. BMC Surgery. 2024;24(1). doi:10.1186/s12893-024-02497-x

BibTeX
@article{Wang2024,
  author = {Wang, Xipeng and Li, Chengqiang and Fan, Junqiang and Hu, Jian and Wang, Mingsong and Li, Hecheng},
  title = {Safety and effectiveness of using Disposable Ultrasonic shears to coagulate 5–7 mm blood vessels: protocol for a prospective, multicenter, randomized, parallel controlled, non-inferiority clinical trial},
  journal = {BMC Surgery},
  year = {2024},
  volume = {24},
  number = {1},
  doi = {10.1186/s12893-024-02497-x}
}
Kostenlos starten →