The optimal introversion angle and length of pedicle screw to avoid L1-S1 vascular damage
BMC Surgery · 2024
DOI: 10.1186/s12893-024-02483-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift BMC Surgery, 2024. Verfasst von Ying Chen und 3 weiteren Autor:innen. Beteiligte Einrichtung: Yichang Central People's Hospital Hubei, Hubei, China. Hauptthemen laut MEDLINE: Pedicle Screws, Lumbar Vertebrae, Vascular System Injuries, Spinal Fusion. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background posterior pedicle screw fixation is common method, one of the most severe complications is iatrogenic vascular damage, no report investigated association of different introversion angles (INTAs) and length of pedicle screw. The aims were to investigate the optimal introversion angle and length of pedicle screw for improving the safety of the operation, and to analyze the differences of vascular damage types at L1-S1.
Methods
Lumbar CT imaging data from110 patients were analyzed by DICOM software, and all parameters were measured by new Cartesian coordinate system, INTAs (L1-L5:5°,10°,15°,S1: 0°, 5°,10°,15°), D O−AVC (the distance between the origin (O) with anterior vertebral cortex (AVC)), D AVC−PGVs (the distance between AVC and the prevertebral great vessels (PGVs)), D O−PGVs (the distance between the O and PGVs). At different INTAs, D AVC−PGVs were divided into four grades: Grade III: D AVC−PGVs ≤ 3 mm, Grade II: 3 mm < D AVC−PGVs ≤ 5 mm, Grade I: D AVC−PGVs > 5 mm, and N: the not touching PGVs.
Results
The optimal INTA was 5° at L1-L3, the left was 5° and the right was 15° at L4, and screw length was less than 50 mm at L1-L4. At L5, the left optimal INTA was 5° and the right was 10°, and screw length was less than 45 mm. The optimal INTA was 15° at S1, and screw length was less than 50 mm. However, screw length was less than 40 mm when the INTA was 0° or 5° at S1.
Conclusions
At L5-S1, the risk of vascular injury is the highest. INTA and length of the pedicle screw in lumbar operation are closely related. 3 mm interval of screw length may be more preferable to reduce vascular damage.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Yichang Central People's Hospital Hubei, Hubei, China.
- Department of Orthopedics, The First College of Clinical Medical Science, China Three Gorges University, Hubei, China.
- Department of Orthopedics, The First College of Clinical Medical Science, China Three Gorges University, Hubei, China. spinedeform2018@sina.com.
- Yichang Central People's Hospital Hubei, Hubei, China. spinedeform2018@sina.com.
Zitieren
APA
Chen, Y., Yang, J., Liang, J., & Wu, W. (2024). The optimal introversion angle and length of pedicle screw to avoid L1-S1 vascular damage. BMC Surgery. https://doi.org/10.1186/s12893-024-02483-3
Vancouver
Chen Y, Yang J, Liang J, Wu W. The optimal introversion angle and length of pedicle screw to avoid L1-S1 vascular damage. BMC Surgery. 2024. doi:10.1186/s12893-024-02483-3
BibTeX
@article{Chen2024,
author = {Chen, Ying and Yang, Junyi and Liang, Jie and Wu, Weifei},
title = {The optimal introversion angle and length of pedicle screw to avoid L1-S1 vascular damage},
journal = {BMC Surgery},
year = {2024},
doi = {10.1186/s12893-024-02483-3}
}
EUVIMED