Biomechanical comparison of polyetheretherketone rods and titanium alloy rods in transforaminal lumbar interbody fusion: a finite element analysis
BMC Surgery · 2024
DOI: 10.1186/s12893-024-02462-8 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift BMC Surgery, 2024. Verfasst von Jie Li und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, 157th West Fifth Road, Xi'an, 710004, Shaanxi Province, China. Hauptthemen laut MEDLINE: Benzophenones, Titanium, Ketones, Polymers. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Key Research and Development Projects of Shaanxi Province.
Abstract (Originalsprache)
Background
Whether polyetheretherketone (PEEK) rods have potential as an alternative to titanium alloy (Ti) rods in transforaminal lumbar interbody fusion (TLIF) remains unclear, especially in cases with insufficient anterior support due to the absence of a cage. The purpose of this study was to investigate biomechanical differences between PEEK rods and Ti rods in TLIF with and without a cage.
Methods
An intact L1-L5 lumbar finite element model was constructed and validated. Accordingly, four TLIF models were developed: (1) Ti rods with a cage; (2) PEEK rods with a cage; (3) Ti rods without a cage; and (4) PEEK rods without a cage. The biomechanical properties were then compared among the four TLIF constructs.
Results
With or without a cage, no obvious differences were found in the effect of PEEK rods and Ti rods on the range of motion, adjacent disc stress, and adjacent facet joint force. Compared to Ti rods, PEEK rods increase the average bone graft strain (270.8-6055.2 µE vs. 319.0-8751.6 µE). Moreover, PEEK rods reduced the stresses on the screw-rod system (23.1–96.0 MPa vs. 7.2–48.4 MPa) but increased the stresses on the cage (4.6–35.2 MPa vs. 5.6–40.9 MPa) and endplates (5.7–32.5 MPa vs. 6.6–37.6 MPa).
Conclusions
Regardless of whether a cage was used for TLIF, PEEK rods theoretically have the potential to serve as an alternative to Ti rods because they may provide certain stability, increase the bone graft strain, and reduce the posterior instrumentation stress, which might promote bony fusion and decrease instrumentation failure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, 157th West Fifth Road, Xi'an, 710004, Shaanxi Province, China.
- Department of Orthopedics, Civil Aviation General Hospital, No. 1, Gaojing Stress, Chaoyang District, Beijing, 100123, China.
- Department of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, 157th West Fifth Road, Xi'an, 710004, Shaanxi Province, China. 13892846285@163.com.
Förderung
- Key Research and Development Projects of Shaanxi Province
Zitieren
APA
Li, J., Cao, S., & Zhao, B. (2024). Biomechanical comparison of polyetheretherketone rods and titanium alloy rods in transforaminal lumbar interbody fusion: a finite element analysis. BMC Surgery. https://doi.org/10.1186/s12893-024-02462-8
Vancouver
Li J, Cao S, Zhao B. Biomechanical comparison of polyetheretherketone rods and titanium alloy rods in transforaminal lumbar interbody fusion: a finite element analysis. BMC Surgery. 2024. doi:10.1186/s12893-024-02462-8
BibTeX
@article{Li2024,
author = {Li, Jie and Cao, Shuai and Zhao, Bo},
title = {Biomechanical comparison of polyetheretherketone rods and titanium alloy rods in transforaminal lumbar interbody fusion: a finite element analysis},
journal = {BMC Surgery},
year = {2024},
doi = {10.1186/s12893-024-02462-8}
}
EUVIMED