Biomechanical analysis of plate versus K-wire fixation for metacarpal shaft fractures with wedge-shaped bone defects
BMC Musculoskeletal Disorders · 2024
DOI: 10.1186/s12891-024-07482-2 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift BMC Musculoskeletal Disorders, 2024. Verfasst von Yung-Cheng Chiu und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Medicine, China Medical University, Taichung, 404, Taiwan. Hauptthemen laut MEDLINE: Metacarpal Bones, Bone Plates, Bone Wires, Fracture Fixation, Internal. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: China Medical University, Taiwan.
Abstract (Originalsprache)
Background
Metacarpal shaft fracture is a common type of hand fracture. Numerous studies have explored fixing transverse fractures in the midshaft of the metacarpal bone. However, this section of the metacarpal bone is often susceptible to high-energy injury, resulting in comminuted fracture or bone loss. In such cases, wedge-shaped bone defects can develop in the metacarpal shaft, increasing the difficulty of performing fracture fixation. Notably, the research on this type of fracture fixation is limited. This study compared the abilities of four fixation methods to fix metacarpal shaft fractures with wedge-shaped bone defects.
Methods
In total, 28 artificial metacarpal bones were used. To create wedge-shaped bone defects, an electric saw was used to create metacarpal shaft fractures at the midshaft of each bone. The artificial metacarpal bones were then divided into four groups for fixation. The bones in the first group were fixed with a dorsal locked plate (DP group), those in the second group were fixed with a volar locked plate (VP group), and those in the third group were fixed by combining dorsal and volar locked plates (DP + VP group), and those in the fourth group were fixed with two K-wires (2 K group). Cantilever bending tests were conducted using a material testing machine to measure yielding force and stiffness. The four groups’ fixation capabilities were then assessed through analysis of variance and Tukey’s test.
Results
The DP + VP group (164.1±44.0 N) achieved a significantly higher yielding force relative to the 2 K group (50.7 ± 8.9 N); the DP group (13.6 ± 3.0 N) and VP group (12.3 ± 1.0 N) did not differ significantly in terms of yielding force, with both achieving lower yielding forces relative to the DP + VP group and 2 K group. The DP + VP group (19.8±6.3 N/mm) achieved the highest level of stiffness, and the other three groups did not differ significantly in terms of stiffness (2 K group, 5.4 ± 1.1 N/mm; DP group, 4.0 ± 0.9 N/mm; VP group, 3.9 ± 1.9 N/mm).
Conclusions
The fixation method involving the combined use of dorsal and volar locked plates (DP + VP group) resulted in optimal outcomes with respect to fixing metacarpal shaft fractures with volar wedge bone defects.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Medicine, China Medical University, Taichung, 404, Taiwan.
- Department of Orthopedic Surgery, China Medical University Hospital, Taichung, 404, Taiwan.
- Department of Orthopaedics, Taichung Veterans General Hospital, Taichung, 407, Taiwan.
- Sports Recreation and Health Management Continuing Studies-Bachelor's Degree Completion Program, Tunghai University, Taichung, 407, Taiwan.
- 3D Printing Medical Research Center, China Medical University Hospital, Taichung, 404, Taiwan.
- Department of Biomedical Engineering, Hungkuang University, Taichung, 433, Taiwan.
Förderung
- China Medical University, Taiwan
Zitieren
APA
Chiu, Y. C., Ho, T. Y., Hsu, C. E., Yeh, C. W., Ting, Y. N., Tsai, M. T., & Hsu, J. T. (2024). Biomechanical analysis of plate versus K-wire fixation for metacarpal shaft fractures with wedge-shaped bone defects. BMC Musculoskeletal Disorders. https://doi.org/10.1186/s12891-024-07482-2
Vancouver
Chiu YC, Ho TY, Hsu CE, Yeh CW, Ting YN, Tsai MT, et al. Biomechanical analysis of plate versus K-wire fixation for metacarpal shaft fractures with wedge-shaped bone defects. BMC Musculoskeletal Disorders. 2024. doi:10.1186/s12891-024-07482-2
BibTeX
@article{Chiu2024,
author = {Chiu, Yung-Cheng and Ho, Tsung-Yu and Hsu, Cheng-En and Yeh, Chen-Wei and Ting, Yen-Nien and Tsai, Ming-Tzu and Hsu, Jui-Ting},
title = {Biomechanical analysis of plate versus K-wire fixation for metacarpal shaft fractures with wedge-shaped bone defects},
journal = {BMC Musculoskeletal Disorders},
year = {2024},
doi = {10.1186/s12891-024-07482-2}
}
EUVIMED