Fachartikel in der Zeitschrift BMC Medical Imaging, 2024. Verfasst von Yun Peng und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, The Second Affiliated Hospital, Jiangxi Medical College, Nanchang University, No. 1 Minde Road, Nanchang, Jiangxi, 330001, C…. Hauptthemen laut MEDLINE: Leukoaraiosis, Feasibility Studies, Ischemic Stroke, Tomography, X-Ray Computed. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the youth research project of Jiangxi science and technology department.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aimed to investigate the feasibility of using computed tomography (CT) attenuation values to differentiate hypodense brain lesions, specifically acute ischemic stroke (AIS) from asymmetric leukoaraiosis (LA) and old cerebral infarction (OCI). Materials and methods This retrospective study included patients with indeterminate hypodense lesions identified via brain CT scans conducted between June 2019 and June 2021. All lesions were confirmed through head MRI/diffusion-weighted imaging within 48 h after CT. CT attenuation values of hypodense lesions and symmetrical control regions were measured. Additionally, CT attenuation value difference (ΔHU) and ratio (Ratio HU ) were calculated. One-way analysis of variance (ANOVA) was used to compare age and CT parameters (CT attenuation values, ΔHU and Ratio HU ) across the groups. Finally, receiver operating characteristic (ROC) analysis was performed to determine the cutoff values for distinguishing hypodense lesions.

Results

A total of 167 lesions from 146 patients were examined. The CT attenuation values for AIS( n = 39), LA( n = 53), and OCI( n = 75) were 18.90 ± 6.40 HU, 17.53 ± 4.67 HU, and 11.90 ± 5.92 HU, respectively. The time interval between symptom onset and CT scans for AIS group was 32.21 ± 26.85 h. ANOVA revealed significant differences among the CT parameters of the hypodense lesion groups (all P < 0.001). The AUC of CT values, ΔHU, and Ratio HU for distinguishing AIS from OCI were 0.802, 0.896 and 0.878, respectively (all P < 0.001). Meanwhile, the AUC for distinguishing OCI from LA was 0.789, 0.883, and 0.857, respectively (all P < 0.001). Nevertheless, none of the parameters could distinguish AIS from LA.

Conclusion

CT attenuation parameters can be utilized to differentiate between AIS and OCI or OCI and LA in indeterminate hypodense lesions on CT images. However, distinguishing AIS from LA remains challenging.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LeukoaraiosisFeasibility StudiesIschemic StrokeTomography, X-Ray ComputedCerebral InfarctionHumansMaleFemaleAgedRetrospective StudiesMiddle AgedDiagnosis, DifferentialROC CurveAged, 80 and over

Stichwörter der Autor:innen

Acute ischemic strokeCTLeukoaraiosisOld cerebral infarction

Autor:innen und Institutionen

  • Department of Radiology, The Second Affiliated Hospital, Jiangxi Medical College, Nanchang University, No. 1 Minde Road, Nanchang, Jiangxi, 330001, China.
  • Intelligent Medical Imaging of Jiangxi Key Laboratory, Nanchang, 330006, China.
  • Department of Radiology, The Second Affiliated Hospital, Jiangxi Medical College, Nanchang University, No. 1 Minde Road, Nanchang, Jiangxi, 330001, China. xiaoyusun1984@163.com.
  • Intelligent Medical Imaging of Jiangxi Key Laboratory, Nanchang, 330006, China. xiaoyusun1984@163.com.

Förderung

  • the youth research project of Jiangxi science and technology department

Zitieren

APA

Peng, Y., Luo, C., Wang, H., Sun, K., Lin, F., Wang, J., Rao, Y., Fan, R., Gong, L., & Sun, X. (2024). Feasibility of CT attenuation values in distinguishing acute ischemic stroke, old cerebral infarction and leukoaraiosis. BMC Medical Imaging. https://doi.org/10.1186/s12880-024-01340-2

Vancouver

Peng Y, Luo C, Wang H, Sun K, Lin F, Wang J, et al. Feasibility of CT attenuation values in distinguishing acute ischemic stroke, old cerebral infarction and leukoaraiosis. BMC Medical Imaging. 2024. doi:10.1186/s12880-024-01340-2

BibTeX
@article{Peng2024,
  author = {Peng, Yun and Luo, Chunyuan and Wang, Heng and Sun, Ke and Lin, Fang and Wang, Jingzhi and Rao, Yutong and Fan, Ruoyun and Gong, Lianggeng and Sun, Xiaoyu},
  title = {Feasibility of CT attenuation values in distinguishing acute ischemic stroke, old cerebral infarction and leukoaraiosis},
  journal = {BMC Medical Imaging},
  year = {2024},
  doi = {10.1186/s12880-024-01340-2}
}
Kostenlos starten →