EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Position-wise comparison of handheld 6-lead ECG versus the standard 12-lead ECG in patients with arrhythmia: comparative study

Young Jun Park, Sujeong Eom, Sang Jun Lee, Yeongyeon Na, Jeonghwa Lim, Minje Park, Hyun Jin Ahn, Mineok Chang, Sunghoon Joo, Min-Soo Ahn

BMC Cardiovascular Disorders · 08.06.2026 · 26 (1)

DOI: 10.1186/s12872-026-05971-x ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift BMC Cardiovascular Disorders, online erschienen am 08.06.2026. Verfasst von Young Jun Park und 9 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Department of Internal Medicine, Korea University College of Medicine and Korea University Anam Hospital, Seoul, Republic of …. Hauptthemen laut MEDLINE: Electrocardiography, Arrhythmias, Cardiac, Heart Rate, Patient Positioning. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Korea Health Industry Development Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

As 12‑lead electrocardiographs (ECGs) require a clinical infrastructure that limits timely access, portable 6‑lead devices may extend diagnostics to community and remote settings. We evaluated the signal equivalence of a handheld 6‑lead ECG (HATIV ® P30) versus the standard 12‑lead in an arrhythmia cohort, considering posture and synchrony.

Methods

In this prospective single-center study, simultaneous 10-s 12-lead ECGs and time-aligned 10-s segments from 30-s 6-lead recordings were obtained from arrhythmia patients in both supine and sitting positions. A blinded electrophysiologist performed rhythm classification and ECG measurements. Diagnostic accuracy and numerical agreement of key parameters (PR interval, QRS duration, QT/QTc intervals, and amplitudes) were evaluated.

Results

A total of 229 paired recordings were analyzed after excluding 6 pairs. The overall diagnostic accuracy of the 6‑lead versus 12‑lead was 99.1% in the supine position ( n = 113) and 99.1% in the sitting position ( n = 116); one atrial flutter was misclassified as atrial fibrillation in each position. Bland–Altman analyses showed small mean differences (12‑lead minus 6‑lead): PR + 12.1/ + 7.4 ms (supine/sitting), QRS − 6.4/ − 6.0 ms, QT − 10.3/ − 5.3 ms, QTc − 11.5/ − 6.4 ms; heart‑rate difference ≈0.03 bpm. The absolute differences were < 20 ms in approximately ~ 70% for PR and ~ 55–62% for QT/QTc. In an exploratory asynchronous pairing (supine 12‑lead vs sitting 6‑lead; n = 103), accuracy decreased to 97.1% and parameter differences widened, consistent with postural/temporal effects.

Conclusions

In patients with arrhythmia, the handheld 6‑lead showed near‑perfect rhythm agreement and small numerical differences versus the 12‑lead under synchronized acquisition in both positions. Asynchronous or posture-mismatched comparisons reduce the agreement, and acquisition conditions should be considered. The 6‑lead may be a practical alternative when the 12‑lead is unavailable in patients with arrhythmia.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectrocardiographyArrhythmias, CardiacHeart RatePatient PositioningSitting PositionHumansFemaleProspective StudiesPredictive Value of TestsMiddle AgedMaleReproducibility of ResultsAction PotentialsAgedSupine PositionEquipment DesignTime FactorsAdult

Stichwörter der Autor:innen

12‑lead ECGArrhythmiaHandheld 6‑lead ECGSignal equivalence

Autor:innen und Institutionen

  • Division of Cardiology, Department of Internal Medicine, Korea University College of Medicine and Korea University Anam Hospital, Seoul, Republic of Korea.
  • VUNO Inc., Seoul, Republic of Korea.
  • Division of Cardiology, Department of Internal Medicine, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea.
  • VUNO Inc., Seoul, Republic of Korea. sunghoon.joo@vuno.co.
  • Division of Cardiology, Department of Internal Medicine, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea. heartsaver@yonsei.ac.kr.

Förderung

  • Korea Health Industry Development Institute

Zitieren

APA

Park, Y. J., Eom, S., Lee, S. J., Na, Y., Lim, J., Park, M., Ahn, H. J., Chang, M., Joo, S., & Ahn, M. S. (2026). Position-wise comparison of handheld 6-lead ECG versus the standard 12-lead ECG in patients with arrhythmia: comparative study. BMC Cardiovascular Disorders, 26(1). https://doi.org/10.1186/s12872-026-05971-x

Vancouver

Park YJ, Eom S, Lee SJ, Na Y, Lim J, Park M, et al. Position-wise comparison of handheld 6-lead ECG versus the standard 12-lead ECG in patients with arrhythmia: comparative study. BMC Cardiovascular Disorders. 2026;26(1). doi:10.1186/s12872-026-05971-x

BibTeX
@article{Park2026,
  author = {Park, Young Jun and Eom, Sujeong and Lee, Sang Jun and Na, Yeongyeon and Lim, Jeonghwa and Park, Minje and Ahn, Hyun Jin and Chang, Mineok and Joo, Sunghoon and Ahn, Min-Soo},
  title = {Position-wise comparison of handheld 6-lead ECG versus the standard 12-lead ECG in patients with arrhythmia: comparative study},
  journal = {BMC Cardiovascular Disorders},
  year = {2026},
  volume = {26},
  number = {1},
  doi = {10.1186/s12872-026-05971-x}
}
Kostenlos starten →