Ultrasonic optic nerve sheath diameter can be used as a diagnostic measure after accidental dural puncture during cesarean section: a case report
BMC Anesthesiology · 2024
DOI: 10.1186/s12871-024-02418-8 ↗Kurz gefasst
Fallbericht in der Zeitschrift BMC Anesthesiology, 2024. Verfasst von Pei Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, The Affiliated Hospital of Qingdao University, Qingdao, 266000, China. Hauptthemen laut MEDLINE: Cesarean Section, Post-Dural Puncture Headache. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Parturients are prone to postdural puncture headache (PDPH) after epidural puncture. Cerebral venous sinus thrombosis (CVST) is a fatal complication of PDPH. The main symptom of both is headache, however, the mechanism is not similar. For persistent PDPH, early differential diagnosis from CVST is essential. Optic nerve sheath diameter (ONSD) measurements can be used to identify changes in intracranial pressure as an auxiliary tool to distinguish the cause of headache. Case presentation The dura of a 32-year-old woman undergoing cesarean section was accidentally penetrated while administering epidural anesthesia, and the patient developed PDPH the subsequent day. The patient refused epidural blood patch (EBP) treatment and was discharged after conservative treatment. Fourteen days post-discharge, she was readmitted for a seizure. Magnetic resonance imaging (MRI) and Magnetic resonance angiography (MRA) indicated low cranial pressure syndrome and superior sagittal sinus thrombosis with acute infarction. The next morning, the EBP was performed with 15 ml autologous blood. Subsequently, the headache symptoms decreased during the day and worsened at night. ONSD measurement suggested dilation of the optic nerve sheath, and subsequently, the patient showed intracranial hypertension with papilledema. After dehydration and anticoagulant treatment, the patient’s symptoms were relieved and she was discharged from the hospital 49 days later.
Conclusions
Headache is the main symptom of PDPH and cerebral venous thrombosis, which are difficult to distinguish. ONSD measurement may help to estimate the intracranial pressure, and early measurement may be helpful for women with PDPH to avoid serious complications, such as CVST.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesiology, The Affiliated Hospital of Qingdao University, Qingdao, 266000, China.
- Department of Emergency surgery, The Affiliated Hospital of Qingdao University, Qingdao, 266000, China.
- Department of Anesthesiology, The Affiliated Hospital of Qingdao University, Qingdao, 266000, China. fengweisdqd@qdu.edu.cn.
Zitieren
APA
Wang, P., Zhou, X., Sheng, F., Wang, X., Shi, C., & Feng, W. (2024). Ultrasonic optic nerve sheath diameter can be used as a diagnostic measure after accidental dural puncture during cesarean section: a case report. BMC Anesthesiology. https://doi.org/10.1186/s12871-024-02418-8
Vancouver
Wang P, Zhou X, Sheng F, Wang X, Shi C, Feng W. Ultrasonic optic nerve sheath diameter can be used as a diagnostic measure after accidental dural puncture during cesarean section: a case report. BMC Anesthesiology. 2024. doi:10.1186/s12871-024-02418-8
BibTeX
@article{Wang2024,
author = {Wang, Pei and Zhou, Xia and Sheng, Fang and Wang, Xiaolong and Shi, Caifeng and Feng, Wei},
title = {Ultrasonic optic nerve sheath diameter can be used as a diagnostic measure after accidental dural puncture during cesarean section: a case report},
journal = {BMC Anesthesiology},
year = {2024},
doi = {10.1186/s12871-024-02418-8}
}
EUVIMED