Comparison of manual and semi-automated delineation of regions of interest for radioligand PET imaging analysis
BMC Nuclear Medicine · 2007
DOI: 10.1186/1471-2385-7-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift BMC Nuclear Medicine, 2007. Verfasst von Tiffany W Chow und 9 weiteren Autor:innen. Beteiligte Einrichtung: Rotman Research Institute, Baycrest, Toronto, Canada. tchow@rotman-baycrest.on.ca. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIA NIH HHS.
Abstract (Originalsprache)
BACKGROUND: As imaging centers produce higher resolution research scans, the number of man-hours required to process regional data has become a major concern. Comparison of automated vs. manual methodology has not been reported for functional imaging. We explored validation of using automation to delineate regions of interest on positron emission tomography (PET) scans. The purpose of this study was to ascertain improvements in image processing time and reproducibility of a semi-automated brain region extraction (SABRE) method over manual delineation of regions of interest (ROIs). METHODS: We compared 2 sets of partial volume corrected serotonin 1a receptor binding potentials (BPs) resulting from manual vs. semi-automated methods. BPs were obtained from subjects meeting consensus criteria for frontotemporal degeneration and from age- and gender-matched healthy controls. Two trained raters provided each set of data to conduct comparisons of inter-rater mean image processing time, rank order of BPs for 9 PET scans, intra- and inter-rater intraclass correlation coefficients (ICC), repeatability coefficients (RC), percentages of the average parameter value (RM%), and effect sizes of either method. RESULTS: SABRE saved approximately 3 hours of processing time per PET subject over manual delineation (p 0.8) for both methods. RC and RM% were lower for the manual method across all ROIs, indicating less intra-rater variance across PET subjects' BPs. CONCLUSION: SABRE demonstrated significant time savings and no significant difference in reproducibility over manual methods, justifying the use of SABRE in serotonin 1a receptor radioligand PET imaging analysis. This implies that semi-automated ROI delineation is a valid methodology for future PET imaging analysis.
Autor:innen und Institutionen
- Rotman Research Institute, Baycrest, Toronto, Canada. tchow@rotman-baycrest.on.ca
Förderung
- NIA NIH HHS
Zitieren
APA
Chow, T. W., Takeshita, S., Honjo, K., Pataky, C. E., St Jacques, P. L., Kusano, M. L., Caldwell, C. B., Ramirez, J., Black, S., & Verhoeff, N. P. (2007). Comparison of manual and semi-automated delineation of regions of interest for radioligand PET imaging analysis. BMC Nuclear Medicine. https://doi.org/10.1186/1471-2385-7-2
Vancouver
Chow TW, Takeshita S, Honjo K, Pataky CE, St Jacques PL, Kusano ML, et al. Comparison of manual and semi-automated delineation of regions of interest for radioligand PET imaging analysis. BMC Nuclear Medicine. 2007. doi:10.1186/1471-2385-7-2
BibTeX
@article{Chow2007,
author = {Chow, Tiffany W and Takeshita, Shinichiro and Honjo, Kie and Pataky, Christina E and St Jacques, Peggy L and Kusano, Maggie L and Caldwell, Curtis B and Ramirez, Joel and Black, Sandra and Verhoeff, Nicolaas P L G},
title = {Comparison of manual and semi-automated delineation of regions of interest for radioligand PET imaging analysis},
journal = {BMC Nuclear Medicine},
year = {2007},
doi = {10.1186/1471-2385-7-2}
}