EUVIMEDEUVIMED entdecken
Open Access

Planar Tc99m – sestamibi scintimammography should be considered cautiously in the axillary evaluation of breast cancer protocols: Results of an international multicenter trial

Teresa Massardo, Omar Alonso, Augusto Llamas-Ollier, Levin Kabasakal, Uma Ravishankar, Rossana Morales, Lucía Delgado, Ajit K Padhy

BMC Nuclear Medicine · 2005

DOI: 10.1186/1471-2385-5-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift BMC Nuclear Medicine, 2005. Verfasst von Teresa Massardo und 7 weiteren Autor:innen. Beteiligte Einrichtung: University of Chile Clinical Hospital, Santiago, Chile. tmassardo@redclinica.cl. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Lymph node status is the most important prognostic indicator in breast cancer in recently diagnosed primary lesion. As a part of an interregional protocol using scintimammography with Tc99m compounds, the value of planar Tc99m sestamibi scanning for axillary lymph node evaluation is presented. Since there is a wide range of reported values, a standardized protocol of planar imaging was performed. METHODS: One hundred and forty-nine female patients were included prospectively from different regions. Their mean age was 55.1 +/- 11.9 years. Histological report was obtained from 2.987 excised lymph nodes from 150 axillas. An early planar chest image was obtained at 10 min in all patients and a delayed one in 95 patients, all images performed with 740-925 MBq dose of Tc99m sestamibi. Blind lecture of all axillary regions was interpreted by 2 independent observers considering any well defined focal area of increased uptake as an involved axilla. Diagnostic values, 95% confidence intervals [CI] and also likelihood ratios (LR) were calculated. RESULTS: Node histology demonstrated tumor involvement in 546 out of 2987 lymph nodes. Sestamibi was positive in 30 axillas (25 true-positive) and negative in 120 (only 55 true-negative). The sensitivity corresponded to 27.8% [CI = 18.9-38.2] and specificity to 91.7% [81.6-97.2]. The positive and negative LR were 3.33 and 0.79, respectively. There was no difference between early and delayed images. Sensitivity was higher in patients with palpable lesions. CONCLUSION: This work confirmed that non tomographic Tc99m sestamibi scintimammography had a very low detection rate for axillary lymph node involvement and it should not be applied for clinical assessment of breast cancer.

Autor:innen und Institutionen

  • University of Chile Clinical Hospital, Santiago, Chile. tmassardo@redclinica.cl

Zitieren

APA

Massardo, T., Alonso, O., Llamas-Ollier, A., Kabasakal, L., Ravishankar, U., Morales, R., Delgado, L., & Padhy, A. K. (2005). Planar Tc99m – sestamibi scintimammography should be considered cautiously in the axillary evaluation of breast cancer protocols: Results of an international multicenter trial. BMC Nuclear Medicine. https://doi.org/10.1186/1471-2385-5-4

Vancouver

Massardo T, Alonso O, Llamas-Ollier A, Kabasakal L, Ravishankar U, Morales R, et al. Planar Tc99m – sestamibi scintimammography should be considered cautiously in the axillary evaluation of breast cancer protocols: Results of an international multicenter trial. BMC Nuclear Medicine. 2005. doi:10.1186/1471-2385-5-4

BibTeX
@article{Massardo2005,
  author = {Massardo, Teresa and Alonso, Omar and Llamas-Ollier, Augusto and Kabasakal, Levin and Ravishankar, Uma and Morales, Rossana and Delgado, Lucía and Padhy, Ajit K},
  title = {Planar Tc99m – sestamibi scintimammography should be considered cautiously in the axillary evaluation of breast cancer protocols: Results of an international multicenter trial},
  journal = {BMC Nuclear Medicine},
  year = {2005},
  doi = {10.1186/1471-2385-5-4}
}
Kostenlos starten →