Threshold of kurtosis on occupational hearing loss associated with non-steady noise

Yang LI, Haiying LIU, Linjie WU, Jinzhe LI, Jiarui XIN, Hua ZOU, Xin SUN, Wei QIU, Changyan YU, Meibian ZHANG

环境与职业医学 · 2025-07 · 42 (7) · 779-785

DOI: 10.11836/jeom24551 ↗

Kurz gefasst

Fachartikel in der Zeitschrift 环境与职业医学, 2025-07. Verfasst von Yang LI und 9 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BackgroundKurtosis reflecting noise's temporal structure is an effective metric for evaluating noise-induced hearing loss (NIHL), and its threshold is still unclear. ObjectiveTo explore the energy range of kurtosis and the threshold of NIHL induced by kurtosis in this energy rangeMethodsUsing cross-sectional design, 4631 noise-exposed workers in manufacturing industry were selected. The hearing loss and noise exposure data of each worker were collected. Logistic regression model was used to establish the dose-response relationship between noise exposure and hearing loss and estimate the range of energy effects. Restricted cubic spline model was utilized to analyze the dose-response relationship curves of kurtosis to noise-induced hearing loss (NIHI) and high-frequency noise-induced hearing loss (HFNIHL) under different 8 h equivalent sound levels (LEX,8 h), as well as to estimate the kurtosis effect threshold. ResultsThe logistic regression model analysis showed that the prevalence of NIHI and HFNIHL increased significantly with increase of LEX,8 h for steady noise; when LEX,8 h of non-steady noise was 80-100 dB(A), the risk of hearing loss increased with an increase in kurtosis (P 100 dB(A), there was no significant relationship between kurtosis and NIHI or HFNIHL. When LEX,8 h was 80-100 dB(A), there was a significant nonlinear dose-response relationship between kurtosis and NIHL or HFNIHL (P 28.08 exerted effect in elevating NIHI or HFNIHL. ConclusionThe effect threshold of kurtosis on NIHL is 28.08 when non-steady noise levels are in the range of 80-100 dB(A). The effect threshold of kurtosis needs further verification.

Schlagwörter

kurtosisnoise-induced hearing lossnon-steady noiseeffect thresholdrestricted cubic spline model

Zitieren

APA

LI, Y., LIU, H., WU, L., LI, J., XIN, J., ZOU, H., SUN, X., QIU, W., YU, C., & ZHANG, M. (2025). Threshold of kurtosis on occupational hearing loss associated with non-steady noise. 环境与职业医学, 42(7), 779-785. https://doi.org/10.11836/jeom24551

Vancouver

LI Y, LIU H, WU L, LI J, XIN J, ZOU H, et al. Threshold of kurtosis on occupational hearing loss associated with non-steady noise. 环境与职业医学. 2025;42(7):779-785. doi:10.11836/jeom24551

BibTeX
@article{LI2025,
  author = {LI, Yang and LIU, Haiying and WU, Linjie and LI, Jinzhe and XIN, Jiarui and ZOU, Hua and SUN, Xin and QIU, Wei and YU, Changyan and ZHANG, Meibian},
  title = {Threshold of kurtosis on occupational hearing loss associated with non-steady noise},
  journal = {环境与职业医学},
  year = {2025},
  volume = {42},
  number = {7},
  pages = {779--785},
  doi = {10.11836/jeom24551}
}