EUVIMEDEUVIMED entdecken
Crossref

Contamination of Legionella pneumophila in metro cooling tower water and its influencing factors in a city

Rong PENG, Bin SHI, Huaiji WANG, Junling LIU, Fang WANG

环境与职业医学 · 2024-12 · 41 (12) · 1414-1421

DOI: 10.11836/jeom24246 ↗

Kurz gefasst

Fachartikel in der Zeitschrift 环境与职业医学, 2024-12. Verfasst von Rong PENG und 4 weiteren Autor:innen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BackgroundThe detection rates of Legionella pneumophila in metro cooling tower water in various cities are relatively high, while studies investigating the trends of Legionella pneumophila pollution and analyzing its influencing factors are still limited. ObjectiveTo investigate the status of Legionella pneumophila contamination in the water of metro cooling towers in a city, to analyze its influencing factors, and to provide a basis for preventing and controlling Legionella pneumophila contamination in metro cooling tower water. MethodsAfter categorizing the metro lines into three groups (>10 years, >5-10 years, and ≤5 years) according to the operating years of each metro line in a city, we randomly selected one line from each group and the selection resulted a total of 58 cooling towers. We collected water samples from the cooling towers during the early, middle, and late stages of cooling tower operation to detect Legionella pneumophila and water quality related indicators. Information on the environment and hygiene management measures of the cooling towers was obtained through on-site investigation and questionnaire survey. Generalized mixed linear models were used to analyze the influencing factors of Legionella pneumophila contamination in cooling tower water. ResultsThe detection rates of Legionella pneumophila in the early, middle, and late stages of cooling tower operation were 25.9%, 77.6%, and 81.0%, respectively. The detection rates in the middle and late stages of operation were significantly higher than that in the early stage (P

Schlagwörter

metrocooling towerlegionella pneumophilainfluencing factor

Zitieren

APA

PENG, R., SHI, B., WANG, H., LIU, J., & WANG, F. (2024). Contamination of Legionella pneumophila in metro cooling tower water and its influencing factors in a city. 环境与职业医学, 41(12), 1414-1421. https://doi.org/10.11836/jeom24246

Vancouver

PENG R, SHI B, WANG H, LIU J, WANG F. Contamination of Legionella pneumophila in metro cooling tower water and its influencing factors in a city. 环境与职业医学. 2024;41(12):1414-1421. doi:10.11836/jeom24246

BibTeX
@article{PENG2024,
  author = {PENG, Rong and SHI, Bin and WANG, Huaiji and LIU, Junling and WANG, Fang},
  title = {Contamination of Legionella pneumophila in metro cooling tower water and its influencing factors in a city},
  journal = {环境与职业医学},
  year = {2024},
  volume = {41},
  number = {12},
  pages = {1414--1421},
  doi = {10.11836/jeom24246}
}
Kostenlos starten →