Association between a recalled positive airway pressure device and incident cancer: a population-based study

Tetyana Kendzerska iD, Sachin R Pendharkar iD, Robert Talarico, Kenneth Blades, Constance Mackenzie, Andrea S Gershon iD, Najib Ayas, Marta Kaminska iD, Mark Fenton, Kerry A McBrien, Steven Hawken, Diana Ratycz und 3 weitere

European Respiratory Journal · 2024

DOI: 10.1183/13993003.00560-2024 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Respiratory Journal, 2024. Verfasst von Tetyana Kendzerska und 14 weiteren Autor:innen. Beteiligte Einrichtung: The Ottawa Hospital Research Institute, Ottawa, ON, Canada tkendzerska@toh.ca. Hauptthemen laut MEDLINE: Neoplasms. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 61 Literaturangaben. Gefördert von: Canadian Institutes of Health Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The real-world consequences of a Philips Respironics recall for positive airway pressure (PAP) devices distributed between 2009 and 2021 are unknown.

Methods

We conducted a retrospective population-based study using health administrative databases (Ontario, Canada) on all new adult PAP users identified through the provincial funding system, free of cancer at baseline, who initiated (claimed) PAP treatment between 2012 and 2018. Everyone was followed from the PAP claim date to the earliest of incident cancer diagnosis, death or end of follow-up (March 2022). We used inverse probability of treatment weighting to balance baseline characteristics between individuals on recalled devices and those on devices from other manufacturers. Weighted hazard ratios of incident cancer were compared between groups.

Results

Of 231 692 individuals identified, 58 204 (25.1%) claimed recalled devices and 173 488 (74.9%) claimed devices from other manufacturers. A meaningful baseline difference between groups (standardised difference ≥0.10) was noted only by location-relevant covariates; other variables were mostly equally distributed (standardised differences ≤0.06). Over a median (interquartile range) follow-up of 6.3 (4.9–8.0) years, 11 166 (4.8%) developed cancer: unadjusted rates per 10 000 person-years of 78.8 (95% CI 76.0–81.7) in the recall group versus 74.0 (95% CI 72.4–75.6) in others (p=0.0034). Propensity score weighting achieved excellent balance in baseline characteristics between groups (standardised differences ≤0.07). On a weighted sample, there was no statistical difference in the hazard of incident cancer between groups: cause-specific hazard ratio (recalled versus others) 0.97 (95% CI 0.89–1.06).

Conclusion

In our real-world population study, compared to other manufacturers and adjusting for confounders, recalled Philips Respironics PAP devices do not appear to be independently associated with developing cancer.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NeoplasmsHumansMaleFemaleMiddle AgedRetrospective StudiesAdultIncidenceAgedOntarioContinuous Positive Airway PressureDatabases, FactualProportional Hazards Models

Autor:innen und Institutionen

  • The Ottawa Hospital Research Institute, Ottawa, ON, Canada tkendzerska@toh.ca.
  • ICES, ON, Canada.
  • Department of Medicine, Faculty of Medicine, University of Ottawa, Ottawa, ON, Canada.
  • School of Epidemiology and Public Health, University of Ottawa, Ottawa, ON, Canada.
  • Department of Medicine, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada.
  • Department of Community Health Sciences, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada.

ORCID-Profile: Tetyana Kendzerska, Sachin R Pendharkar, Andrea S Gershon, Marta Kaminska

Förderung

  • Canadian Institutes of Health Research

Zitieren

APA

Kendzerska, T., Pendharkar, S. R., Talarico, R., Blades, K., Mackenzie, C., Gershon, A. S., Ayas, N., Kaminska, M., Fenton, M., McBrien, K. A., Hawken, S., Ratycz, D., Lishchenko, V., Owens, R. L., & Povitz, M. (2024). Association between a recalled positive airway pressure device and incident cancer: a population-based study. European Respiratory Journal. https://doi.org/10.1183/13993003.00560-2024

Vancouver

Kendzerska T, Pendharkar SR, Talarico R, Blades K, Mackenzie C, Gershon AS, et al. Association between a recalled positive airway pressure device and incident cancer: a population-based study. European Respiratory Journal. 2024. doi:10.1183/13993003.00560-2024

BibTeX
@article{Kendzerska2024,
  author = {Kendzerska, Tetyana and Pendharkar, Sachin R and Talarico, Robert and Blades, Kenneth and Mackenzie, Constance and Gershon, Andrea S and Ayas, Najib and Kaminska, Marta and Fenton, Mark and McBrien, Kerry A and Hawken, Steven and Ratycz, Diana and Lishchenko, Vadym and Owens, Robert L and Povitz, Marcus},