ERS technical standard: Global Lung Function Initiative reference values for exhaled nitric oxide fraction ( F ENO 50 )
European Respiratory Journal · 2024-01 · 63 (1) · 2300370
DOI: 10.1183/13993003.00370-2023 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Respiratory Journal, online erschienen am 16.11.2023. Verfasst von Marieann Högman und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Sciences, Respiratory, Allergy and Sleep Research, Uppsala University, Uppsala, Sweden. Hauptthemen laut MEDLINE: Nitric Oxide, Asthma. Die Arbeit wurde bisher 36-mal zitiert (Crossref) und nennt 36 Literaturangaben.
Abstract (Originalsprache)
Background
Elevated exhaled nitric oxide fraction at a flow rate of 50 mL·s −1 ( F ENO 50 ) is an important indicator of T-helper 2-driven airway inflammation and may aid clinicians in the diagnosis and monitoring of asthma. This study aimed to derive Global Lung Function Initiative reference equations and the upper limit of normal for F ENO 50 .
Methods
Available individual F ENO 50 data were collated and harmonised using consensus-derived variables and definitions. Data collected from individuals who met the harmonised definition of “healthy” were analysed using the generalised additive models of location, scale and shape (GAMLSS) technique.
Results
Data were retrospectively collated from 34 782 individuals from 34 sites in 15 countries, of whom 8022 met the definition of healthy (19 sites, 11 countries). Overall, height, age and sex only explained 12% of the between-subject variability of F ENO 50 (R 2 =0.12). F ENO device was neccessary as a predictor of F ENO 50 , such that the healthy range of values and the upper limit of normal varied depending on which device was used. The range of F ENO 50 values observed in healthy individuals was also very wide, and the heterogeneity was partially explained by the device used. When analysing a subset of data in which F ENO 50 was measured using the same device and a stricter definition of health (n=1027), between-site heterogeneity remained.
Conclusion
Available F ENO 50 data collected from different sites using different protocols and devices were too variable to develop a single all-age reference equation. Further standardisation of F ENO devices and measurement are required before population reference values might be derived.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Medical Sciences, Respiratory, Allergy and Sleep Research, Uppsala University, Uppsala, Sweden.
- Michael G. DeGroote School of Medicine, McMaster University, Hamilton, ON, Canada.
- Department of Community Health and Epidemiology, Dalhousie University, Halifax, NS, Canada.
- Division of Occupational and Environmental Medicine, Epidemiology, Biostatistics and Prevention Institute, University of Zurich and University Hospital Zurich, Zurich, Switzerland.
- Department of Medical Sciences, Clinical Physiology, Uppsala University, Uppsala, Sweden.
- Lung Function Department, Isala Hospital, Zwolle, The Netherlands.
ORCID-Profile: Marieann Högman, Andrei Malinovschi, Thomas Radtke, Irene Steenbruggen, Steve Turner, Anh Tuan Dinh-Xuan
Zitieren
APA
Högman, M., Bowerman, C., Chavez, L., Dressel, H., Malinovschi, A., Radtke, T., Stanojevic, S., Steenbruggen, I., Turner, S., Dinh-Xuan, A. T., & Global Lung Function Initiative FENO Task Force (2024). ERS technical standard: Global Lung Function Initiative reference values for exhaled nitric oxide fraction ( F ENO 50 ). European Respiratory Journal, 63(1), 2300370. https://doi.org/10.1183/13993003.00370-2023
Vancouver
Högman M, Bowerman C, Chavez L, Dressel H, Malinovschi A, Radtke T, et al. ERS technical standard: Global Lung Function Initiative reference values for exhaled nitric oxide fraction ( F ENO 50 ). European Respiratory Journal. 2024;63(1):2300370. doi:10.1183/13993003.00370-2023
BibTeX
@article{Hgman2024,
author = {Högman, Marieann and Bowerman, Cole and Chavez, Luis and Dressel, Holger and Malinovschi, Andrei and Radtke, Thomas and Stanojevic, Sanja and Steenbruggen, Irene and Turner, Steve and Dinh-Xuan, Anh Tuan and Global Lung Function Initiative FENO Task Force, Global Lung Function Initiative FENO Task Force},
title = {ERS technical standard: Global Lung Function Initiative reference values for exhaled nitric oxide fraction ( F ENO 50 )},
journal = {European Respiratory Journal},
year = {2024},
volume = {63},
number = {1},
pages = {2300370},
doi = {10.1183/13993003.00370-2023}
}
EUVIMED