Fachartikel in der Zeitschrift British Journal of Orthodontics, online erschienen am 01.05.1992. Verfasst von B Boysen und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, Royal Dental College, Aarhus C, Denmark. Hauptthemen laut MEDLINE: Activator Appliances, Orthodontic Appliances, Removable. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The aim of the study was to evaluate in a three-dimensional manner the dentoskeletàl changes after slow maxillary expansion. The sample consisted of 34 children with a unilateral, symmetrical posterior cross-bite. Half of the children were treated with a quad-helix and the rest with a removable appliance. Assessment of the changes was made with study casts, and frontal and lateral cephalograms, before treatment, at the end of the expansion, after a retention period of 3 months, and after a post-retention period of 3 months. The results showed that sufficient expansion of the dental arches took place in both groups. The expansion expressed in the molar region in the quad-helix group was mostly due to buccal translation of the teeth and in the removable appliance group due to buccal tipping. The quad-helix group showed somewhat greater basal expansion than the removable appliance group, though the basal expansion in both groups was rather small. A tendency towards an increase of the NL/ML angle characterized the removable appliance group, but the opposite pattern was present in the quad-helix group.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Activator AppliancesOrthodontic Appliances, RemovableCephalometryChildEvaluation Studies as TopicFacial BonesFemaleHumansMaleMalocclusionMandibleMaxillaModels, DentalOrbitOrthodontic Appliance DesignOrthodontic WiresPalatal Expansion TechniqueSkullStainless SteelTooth

Substanzen

Stainless Steel

Autor:innen und Institutionen

  • Department of Orthodontics, Royal Dental College, Aarhus C, Denmark.

Zitieren

APA

Boysen, B., La Cour, K., Athanasiou, A. E., & Gjessing, P. E. (1992). Three-dimensional Evaluation of Dentoskeletal Changes after Posterior Cross-bite Correction by Quad-Helix or Removable Appliances. British Journal of Orthodontics, 19(2), 97-107. https://doi.org/10.1179/bjo.19.2.97

Vancouver

Boysen B, La Cour K, Athanasiou AE, Gjessing PE. Three-dimensional Evaluation of Dentoskeletal Changes after Posterior Cross-bite Correction by Quad-Helix or Removable Appliances. British Journal of Orthodontics. 1992;19(2):97-107. doi:10.1179/bjo.19.2.97

BibTeX
@article{Boysen1992,
  author = {Boysen, B and La Cour, K and Athanasiou, A E and Gjessing, P E},
  title = {Three-dimensional Evaluation of Dentoskeletal Changes after Posterior Cross-bite Correction by Quad-Helix or Removable Appliances},
  journal = {British Journal of Orthodontics},
  year = {1992},
  volume = {19},
  number = {2},
  pages = {97--107},
  doi = {10.1179/bjo.19.2.97}
}
Kostenlos starten →