Application of a circulating-cathodic-antigen (CCA) strip test and real-time PCR, in comparison with microscopy, for the detection of Schistosoma haematobium in urine samples from Ghana
Annals of Tropical Medicine & Parasitology · 2008-10 · 102 (7) · 625-633
DOI: 10.1179/136485908x337490 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Tropical Medicine & Parasitology, online erschienen am 18.07.2013. Verfasst von B B Obeng und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Parasitology, Leiden University Medical Centre (LUMC), P4-37a, Albinusdreef 2333 ZA Leiden, The Netherlands. Hauptthemen laut MEDLINE: Reagent Strips. Die Arbeit wurde bisher 171-mal zitiert (Crossref) und nennt 33 Literaturangaben.
Abstract (Originalsprache)
In the detection of parasitic infection, the traditional methods based on microscopy often have low sensitivity and/or specificity compared with the newer, molecular tests. An assay based on real-time PCR and a reagent strip test for detecting circulating cathodic antigen (CCA) have both now been compared with urine filtration and microscopy, in the detection of Schistosoma haematobium infections. Urine samples, obtained from 74 'cases' in areas of Ghana with endemic S. haematobium and 79 'controls' from non-endemic areas, were each checked using the three methods. With the results of the filtration and microscopy taken as the 'gold standard', real-time PCR was found to be 100% specific and 89% sensitive whereas the CCA strips were 91% specific and 41% sensitive. With the samples found to contain > or =50 eggs/10 ml (indicating relatively intense infections), the sensitivities of the PCR and CCA were higher, at 100% and 62%, respectively. As expected, egg counts were negatively correlated with the number of amplification cycles needed, in the PCR, to give a signal that exceeded the background (r=-0.38; P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Parasitology, Leiden University Medical Centre (LUMC), P4-37a, Albinusdreef 2333 ZA Leiden, The Netherlands.
Zitieren
APA
Obeng, B. B., Aryeetey, Y. A., de Dood, C. J., Amoah, A. S., Larbi, I. A., Deelder, A. M., Yazdanbakhsh, M., Hartgers, F. C., Boakye, D. A., Verweij, J. J., van Dam, G. J., & van Lieshout, L. (2008). Application of a circulating-cathodic-antigen (CCA) strip test and real-time PCR, in comparison with microscopy, for the detection of Schistosoma haematobium in urine samples from Ghana. Annals of Tropical Medicine & Parasitology, 102(7), 625-633. https://doi.org/10.1179/136485908x337490
Vancouver
Obeng BB, Aryeetey YA, de Dood CJ, Amoah AS, Larbi IA, Deelder AM, et al. Application of a circulating-cathodic-antigen (CCA) strip test and real-time PCR, in comparison with microscopy, for the detection of Schistosoma haematobium in urine samples from Ghana. Annals of Tropical Medicine & Parasitology. 2008;102(7):625-633. doi:10.1179/136485908x337490
BibTeX
@article{Obeng2008,
author = {Obeng, B B and Aryeetey, Y A and de Dood, C J and Amoah, A S and Larbi, I A and Deelder, A M and Yazdanbakhsh, M and Hartgers, F C and Boakye, D A and Verweij, J J and van Dam, G J and van Lieshout, L},
title = {Application of a circulating-cathodic-antigen (CCA) strip test and real-time PCR, in comparison with microscopy, for the detection of Schistosoma haematobium in urine samples from Ghana},
journal = {Annals of Tropical Medicine & Parasitology},
year = {2008},
volume = {102},
number = {7},
pages = {625--633},
doi = {10.1179/136485908x337490}
}
EUVIMED