Echo Intensity Reliability From Two Ultrasound Systems
Journal of Diagnostic Medical Sonography · 2020-09 · 36 (5) · 464-469
DOI: 10.1177/8756479320929030 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Diagnostic Medical Sonography, online erschienen am 19.06.2020. Verfasst von Rodrigo Rabello und 5 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 33 Literaturangaben.
Abstract (Originalsprache)
Objective
Echo intensity measurements are highly influenced by ultrasound system and parameters used for measurement, making comparisons of results obtained from different ultrasound machines difficult. Therefore, it is necessary to understand how reliability changes when using different ultrasound systems and parameters. Materials and Methods: ALOKA SSD4000 and GE LOGIQ P6 systems were used to compare rectus femoris echo intensity in 16 healthy young subjects (eight women) using different depths (D), gains (G), and frequencies (F). The following settings were adopted: ALOKA 1 (D6/G30/F7.5), ALOKA 2 (D6/G45/F7.5), ALOKA 3 (D6/G30/F10), LOGIQ 1 (D6/G50/F15), LOGIQ 2 (D6/G0/F15), LOGIQ 3 (D6/G0/F10), and LOGIQ 4 (D6/G30/F10). Intraclass correlation coefficient, standard error of the measure, minimum difference, and Bland-Altman tests were performed to calculate reliability and agreement between systems’ settings.
Results
ALOKA 1 × LOGIQ 1 , ALOKA 1 × LOGIQ 4 , and ALOKA 3 × LOGIQ 1 showed moderate to high ICCs and agreement on the Bland-Altman test.
Conclusion
Echo intensity varies between systems and parameters, but reliability can be increased by adjusting the ultrasound settings.
Zitieren
APA
Rabello, R., Pompeo, K. D., Paz, I. D. A., Lanferdini, F. J., Pinto, R. S., & Vaz, M. A. (2020). Echo Intensity Reliability From Two Ultrasound Systems. Journal of Diagnostic Medical Sonography, 36(5), 464-469. https://doi.org/10.1177/8756479320929030
Vancouver
Rabello R, Pompeo KD, Paz IDA, Lanferdini FJ, Pinto RS, Vaz MA. Echo Intensity Reliability From Two Ultrasound Systems. Journal of Diagnostic Medical Sonography. 2020;36(5):464-469. doi:10.1177/8756479320929030
BibTeX
@article{Rabello2020,
author = {Rabello, Rodrigo and Pompeo, Klauber D. and Paz, Isabel de Almeida and Lanferdini, Fabio J. and Pinto, Ronei S. and Vaz, Marco A.},
title = {Echo Intensity Reliability From Two Ultrasound Systems},
journal = {Journal of Diagnostic Medical Sonography},
year = {2020},
volume = {36},
number = {5},
pages = {464--469},
doi = {10.1177/8756479320929030}
}
EUVIMED