Proof-of-principle evaluation of a real-time 3D video respiratory monitoring device

Kévin Albert, Florian Chavernac, Hoang Vu Huy, Srinivasan Ramachandran, Rita Noumeir, David Brossier, Philippe Jouvet

Respiratory Care Reports · 2026-08 · 2

DOI: 10.1177/30682576261474152 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Respiratory Care Reports, online erschienen am 11.08.2026. Verfasst von Kévin Albert und 6 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Canada Foundation for Innovation, CHU Sainte-Justine Foundation, Fonds de Recherche du Québec – Santé.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Continuous monitoring of breathing frequency ( f ), tidal volume ( V T ), and flow parameters is essential in intensive care units (ICUs) for detecting early respiratory deterioration. In spontaneously breathing ICU patients, these parameters are difficult to measure continuously because spirometry requires cooperation and interrupts care. Non-contact depth-based sensing may offer a practical and real-time alternative for bedside respiratory monitoring.

Methods

This prospective study evaluated the accuracy of a Kinect Azure–based RGB-D camera system (3DRespiView) designed for automated and non-invasive respiratory monitoring in an ICU-oriented configuration. Healthy adult volunteers underwent simultaneous recordings with a spirometer (reference) and the 3DRespiView system. Each participant completed three 30-second sessions of spontaneous breathing in the supine position. The system automatically detected the thorax, quantified 3D surface displacement, and extracted respiratory parameters including V T , f , inspiratory time ( T i ), expiratory time ( T e ), and peak inspiratory and expiratory flows (PIF/PEF). Agreement was assessed using Bland–Altman analysis, correlation coefficients, mean absolute error (MAE), and root mean square error (RMSE).

Results

Eight participants completed 24 paired recordings. 3DRespiView demonstrated high accuracy across all parameters. For V T , the Bland–Altman bias was 24.1 mL with limits of agreement −17.7 to +66.0 mL; MAE was 26 mL (3.5%) and RMSE 33 mL (4.9%), with a strong correlation (R 2 = 0.99). Breathing frequency ( f ) showed perfect agreement with spirometry (MAE = 0%, R 2 = 1), and T i and T e showed MAEs of 0.10 s (5.2%) and 0.09 s (4.1%), respectively. PIF and PEF showed MAEs of 21 mL/s (3.6%) and 28 mL/s (5.6%), with correlations ranging from R 2 = 0.93 to 0.98. Volume–time waveform comparison showed close temporal alignment between modalities.

Conclusions

3DRespiView demonstrates the potential for accurate, automated, and real-time estimation of respiratory parameters using a non-contact 3D camera. These findings support the technical validity of the approach and highlight its future potential for continuous bedside respiratory monitoring in the ICU.

Förderung

  • Canada Foundation for Innovation
  • CHU Sainte-Justine Foundation
  • Fonds de Recherche du Québec – Santé
  • AIRS Québec Research Network
  • Ministry of Health of Quebec

Zitieren

APA

Albert, K., Chavernac, F., Huy, H. V., Ramachandran, S., Noumeir, R., Brossier, D., & Jouvet, P. (2026). Proof-of-principle evaluation of a real-time 3D video respiratory monitoring device. Respiratory Care Reports, 2. https://doi.org/10.1177/30682576261474152

Vancouver

Albert K, Chavernac F, Huy HV, Ramachandran S, Noumeir R, Brossier D, et al. Proof-of-principle evaluation of a real-time 3D video respiratory monitoring device. Respiratory Care Reports. 2026;2. doi:10.1177/30682576261474152

BibTeX
@article{Albert2026,
  author = {Albert, Kévin and Chavernac, Florian and Huy, Hoang Vu and Ramachandran, Srinivasan and Noumeir, Rita and Brossier, David and Jouvet, Philippe},
  title = {Proof-of-principle evaluation of a real-time 3D video respiratory monitoring device},
  journal = {Respiratory Care Reports},
  year = {2026},
  volume = {2},
  doi = {10.1177/30682576261474152}
}
Kostenlos starten →