EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

The effect of single-prong high-flow nasal cannula therapy on CO 2 clearance

Robert P. Kacinski, Wayne Strasser, Jonathan B. Waugh

Respiratory Care Reports · 2026-04 · 2

DOI: 10.1177/30682576261442834 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Respiratory Care Reports, online erschienen am 30.04.2026. Verfasst von Robert P. Kacinski und 2 weiteren Autor:innen. Die Arbeit nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Vapotherm Inc..

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

High-flow nasal cannula therapy has multiple proposed benefits, one of which is the clearance of exhaled CO 2 from the upper airway. The removal of exhaled CO 2 is made more difficult when the patient has a closed or partially closed mouth, as this removes or restricts the primary escape route for CO 2 -laden exhaled flow. It is proposed that this increased flush difficulty could be partially alleviated by using a single-prong cannula design, therefore allowing exhaled flow to be evacuated out of the open naris.

Methods

Unsteady simulations were run to investigate the effect that the proposed single-prong high-flow therapy has on CO 2 flush at intermediate and high flush difficulty scenarios. Single- and dual-prong geometries were tested under identical conditions including simulated mouth opening, respiratory cycle, airway geometry, and therapy flow setting. Therapy flows tested with both cannula geometries ranged from 12 to 45 L/min. All data discussed in this study was collected from computational models.

Results

The single-prong geometry resulted in less CO 2 inhalation when all other factors were equal. The distinction between cannula geometries grew as therapy flow was decreased and as the mouth opening was decreased. Pathlines, colored by residence time in the upper airway, were released from the trachea. The pathlines showed longer expiratory flow residence times in the airway for the dual-prong cannula, reinforcing the notion that that the single-prong cannula improves the efficiency of expiratory flow removal.

Conclusions

The results can be used to provide a framework for clinical studies investigating the potential benefits of single-prong cannulas. This would be particularly important in difficult-to-flush scenarios such as when the patient’s mouth is fully closed.

Förderung

  • Vapotherm Inc.

Zitieren

APA

Kacinski, R. P., Strasser, W., & Waugh, J. B. (2026). The effect of single-prong high-flow nasal cannula therapy on CO 2 clearance. Respiratory Care Reports, 2. https://doi.org/10.1177/30682576261442834

Vancouver

Kacinski RP, Strasser W, Waugh JB. The effect of single-prong high-flow nasal cannula therapy on CO 2 clearance. Respiratory Care Reports. 2026;2. doi:10.1177/30682576261442834

BibTeX
@article{Kacinski2026,
  author = {Kacinski, Robert P. and Strasser, Wayne and Waugh, Jonathan B.},
  title = {The effect of single-prong high-flow nasal cannula therapy on CO 2 clearance},
  journal = {Respiratory Care Reports},
  year = {2026},
  volume = {2},
  doi = {10.1177/30682576261442834}
}