EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Comparing Designed Training Sets to Optimize Multivariate Regression Models for Pr, Nd, and Nitric Acid Using Spectrophotometry

Luke R. Sadergaski, Hunter B. Andrews, David Rai, Vasileios A. Anagnostopoulos

Applied Spectroscopy Practica · 2024

DOI: 10.1177/27551857241243083 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Spectroscopy Practica, 2024. Verfasst von Luke R. Sadergaski und 3 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: US Department of Energy Isotope Program..

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Chemometric regression models were developed for the quantification of praseodymium (Pr, 0–1000 µg/mL), neodymium (Nd, 0–1000 µg/mL), and nitric acid (HNO 3 , 0.1–5 M) using spectrophotometry. Designed calibration sets were composed of 20 samples each: 10 model points and 10 lack-of-fit (LOF) points. The D-optimal designs effectively minimized the number of samples required to build models, and each design resulted in similar prediction performance, suggesting that statistical design of experiments can provide a reliable framework for selecting training set samples in three-variable systems. Partial least squares regression (PLSR) models were validated against a one-factor-at-a-time validation set composed of 125 samples (three variables, five levels). The top PLS-1 models resulted in average percent root mean square error of prediction error values of 3.5%, 1.7%, and 1.2% for Pr(III), Nd(III), and HNO 3 , respectively. Power set augmentations of the model and LOF samples were investigated to optimize the number of training set samples. PLSR models built using just required model points (10) had similar predictive capabilities as models including the LOF points (20) but with fewer samples. The number of validation samples was also varied systematically to learn how many samples are needed to validate regression models. This work addresses long-standing questions in the field of chemometrics to help make this approach amenable to the near-real-time quantification of hazardous species in remote settings.

Förderung

  • US Department of Energy Isotope Program.

Zitieren

APA

Sadergaski, L. R., Andrews, H. B., Rai, D., & Anagnostopoulos, V. A. (2024). Comparing Designed Training Sets to Optimize Multivariate Regression Models for Pr, Nd, and Nitric Acid Using Spectrophotometry. Applied Spectroscopy Practica. https://doi.org/10.1177/27551857241243083

Vancouver

Sadergaski LR, Andrews HB, Rai D, Anagnostopoulos VA. Comparing Designed Training Sets to Optimize Multivariate Regression Models for Pr, Nd, and Nitric Acid Using Spectrophotometry. Applied Spectroscopy Practica. 2024. doi:10.1177/27551857241243083

BibTeX
@article{Sadergaski2024,
  author = {Sadergaski, Luke R. and Andrews, Hunter B. and Rai, David and Anagnostopoulos, Vasileios A.},
  title = {Comparing Designed Training Sets to Optimize Multivariate Regression Models for Pr, Nd, and Nitric Acid Using Spectrophotometry},
  journal = {Applied Spectroscopy Practica},
  year = {2024},
  doi = {10.1177/27551857241243083}
}
Kostenlos starten →